NEC Univerge SV8100 Features And Specifications Manual page 1614

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 12.0
Program
Program Name
Number
24-02-07
System Options for Transfer –
Trunk-to-Trunk Transfer Release
Warning Tone
24-02-10
System Options for Transfer –
Disconnect Trunk-to-Trunk
25-07-07
System Timers for VRS/DISA –
Ling Conversation Warning Tone
Time
25-07-08
System Timers for VRS/DISA –
Long Conversation Disconnect
Time
Method B – Tandem Trunking with Transfer Key:
Program
Program Name
Number
14-01-04
Basic Trunk Data Setup –
Transmit Gain Level for
Conference and Transfer Calls
14-01-05
Basic Trunk Data Setup –
Receive Gain Level for
Conference and Transfer Calls
14-01-13
Basic Trunk Data Setup –
Trunk-to-Trunk Transfer
2 - 1584
Description/Comments
This timer starts when a trunk
begins talking with another trunk
(for example: Trunk-to-Trunk
Transfer, outgoing from trunk,
Tandem Trunking).
When this time expires, a warning
tone is heard. If Program 24-02-10
is set, the conversation
disconnects after time expires.
This time is set again when the
external digit time expires. One of
the trunks used must be an analog
trunk (or leased line).
This timer starts after the
Trunk-to-Trunk warning tone is
heard.
Determine the time a DISA caller
or any trunk-to-trunk (such as
Tandem Trunking) conversation
can talk before the Long
Conversation tone is heard.
Determine the time the system
waits before disconnecting a DISA
caller or any trunk-to-trunk (such
as Tandem Trunking)
conversation call after the Long
Conversation tone is heard.
Description/Comments
Select the Transmit CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
Select the Receive CODEC gain
level used by the trunk when it is
part of an Unsupervised
Conference.
For each trunk, enter 1 to enable
loop supervision.
Tandem Trunking (Unsupervised Conference)
UNIVERGE SV8100
Assigned Data
1
0~64800 (seconds)
(default = 1800)
0~64800 (seconds)
(default = 0)
0~64800 (seconds)
(default = 3600)
0~64800 (seconds)
(default = 10)
Assigned Data
1
1~63(-15.5dB~
+15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
1~63(-15.5dB~
+15.5dB in 0.5dB
intervals)
[default = 16 (-8dB)]
0 = Disable
1 = Enable
(default = 1)
Level
2
3
Level
2
3

Hide quick links:

Advertisement

Table of Contents
loading