NEC Univerge SV8100 Features And Specifications Manual page 1535

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
51-16-01
NetLink System Data Replication
Mode Setting – System Data
Replication Mode
51-16-02
NetLink System Data Replication
Mode Setting – System Data
Replication Time Setting
51-16-03
NetLink System Data Replication
Mode Setting – System Data
Replication Interval Setting
51-16-04
Replication Time Stamp
Show next replication time.
(Read Only)
51-16-05
NetLink System Data Replication
Mode Setting – System Data
Replication Wait Time
51-16-06
NetLink System Data Replication
Mode Setting – System Data
Replication Interval
51-17-01
NetLink DT700 Server Individual
Information Setup – Registrar
Port
51-17-02
NetLink DT700 Server Individual
Information Setup – Subscribe
Session Port
51-18-01
Netlink Configuration Options –
Netlink Fail-Over Limit
51-19-01
NetLink IP Trunk (SIP) Calling
Party Number Setup for
Extension – NetLink CPN
Transmission
SV8100 NetLink
Description/Comments
Set the synchronous mode of the
system data. When set to 1 , the
systems are synchronized at the
time set in Item 02 below.
When set to 2, the systems are
synchronized at regular time
intervals set in Item 03 below.
Set the time of day that both
systems synchronize database
(when Item 01 is set to 1).
Set the time that both systems
synchronize database (when Item
01 is set to 2).
Month: 0~12
Day: 0~31
Hour: 00~23
Minute: 00~59.
Set the wait time until replication
starts when NetLink is created.
Set an interval time to start
replication to the next node after
replication to one node is
completed.
Use to set the SIP Register Port of
each system.
Use to set the SIP Subscribe
Session Port number of each
system when NetLink is used.
When tear-down of network was
repeated more than the specified
times, NetLink is operated
stand-alone.
This program assigns
transmission of Calling Party
Number (CPN) from Program
21-19 for each secondary system.
The transmission applies for every
extension.
Assigned Data
1
0 = Disable
1 = Setting Time Mode
2 = Interval Mode
(default = 2)
0000~2359
(default = 0000)
15~1440 (minutes)
(default = 30)
(default not assigned)
1~86400 (seconds)
(default = 180)
0~86400 (seconds)
(default = 1)
0~65535
(default = 5080)
0~65535
(default = 5081)
0, 2~10
(0 = Infinity)
(default = 0)
0 = Disable
1 = Enable
(default = 1)
Issue 12.0
Level
2
3
2 - 1505

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents