Label
F1, F2, F3
AC PWR
MagneMover LITE User Manual
Table 4-27: MM LITE Power Supply Fuses
6.3 x 32 mm, 250V AC (125V DC), 10 A ceramic slow blow fuse
5x20 mm, 250V, 10 A time-lag fuse
Table 4-28: MM LITE Power Supply DC Power Pinouts
V+ Propulsion
V+ Logic
*
V- Return
RTN
*
MagneMotion recommends tying V- Return to RTN.
Table 4-29: MM LITE Power Supply DC Enable
Pin
1
2
3
4
5
6
7
8
9
*
DC-OK signal is 0...1V when the PS is off and between
3.3...5.6V when the PS is on. The sinking current is 10 mA max-
imum.
Can be shorted via a transistor to enable propulsion power. The
sinking current is 20 mA maximum.
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Specifications and Site Requirements
Description
Individual Terminals
Black
White
Red
Green
3
2
8
7
DE-9, Socket
Signal
*
DC-OK
RTN
+Bus Enable
-Bus Enable
Electrical Specifications