B.
Create the Node Controller Configuration File (node_configuration.xml) to
define the components and operating parameters of the transport system.
4.
Set the IP address for each node controller and specify the node controller to be used
as the high-level controller (see the Node Controller Interface User Manual,
MMI-UM001).
5.
Verify that the installation is complete and the system is ready for use:
System Check-out on page
System Power-up on page
6.
Upload the configuration, image, and type files to each node controller using the node
controller web interface (see
the Node Controller Interface User Manual, MMI-UM001).
Once configured, the node controllers can be used to simulate the transport system, see
Transport System Simulation on page
7.
When using motors with Ethernet communication, create the MICS file (see
Motor MICS File on page
Power-up on page
8.
Program the motors using the Motor ERF Image files (see
on page
NCHost TCP Interface Utility User Manual, MMI-UM010).
9.
If using the LSM Synchronization option, install the components of the option on the
transport system and configure the SYNC IT
the LSM Synchronization Option User Manual, MMI-UM005.
10.
Test and debug the transport system by using the NCHost TCP Interface Utility and
Demo Scripts (see
face Utility User Manual, MMI-UM010). NCHost provides an easy method to verify
proper operation and make adjustments such as refining the control loop tuning.
NOTE: The NCHost TCP Interface Utility is for test and verification trials only. The
11.
Configure the host controller to control the MM LITE transport system as required to
meet the material movement needs of the facility where the system is installed. See:
Transport System Operation on page
Shutdown on page
When using TCP/IP communication, see the Host Controller TCP/IP Communication
Protocol User Manual, MMI-UM003. When using EtherNet/IP communication, see
the Host Controller EtherNet/IP Communication Protocol User Manual,
MMI-UM004.
MagneMover LITE User Manual
Getting Started with the MagneMover LITE Transport System
Node Controller Software Installation on page 308
97) and provision the motors (see
310).
308, the Node Controller Interface User Manual, MMI-UM001, and the
Check-out and Power-up on page 309
host controller must be used to control the MM LITE transport system after
verification of functionality.
344.
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
309.
310.
334.
controller for operation as described in
343.
Introduction
Ethernet
Step 11
of
System
Motor Software Installation
and the NCHost TCP Inter-
and
49

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MagneMotion MagneMover LITE and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents