1.
Connect a power cable to either the J1 or J2 terminals on the power supply. Reference
the labels on the wires to identify the correct connections (see
and
Figure
•
Make sure that the power supply is properly grounded.
•
Make sure that the power cables are sized for the full load of all motors down-
stream from the connection.
2.
Run the power cable from the power supply to the first motor in the path. Route the
cable in the cable chase so it is shielded from damage and can be easily accessed for
service.
3.
Connect a T-splitter power cable to the motor; finger-tighten only – do not use tools to
tighten.
4.
Connect the power cable to the T-splitter power cable; finger-tighten only – do not use
tools to tighten.
5.
Connect a power bus cable to the T-splitter; finger-tighten only – do not use tools to
tighten. Route the cable in the cable chase so it is shielded from damage and can be
easily accessed for service.
6.
Connect a T-splitter power cable to the next motor; finger-tighten only – do not use
tools to tighten.
7.
Connect the power bus cable from the last motor to the T-splitter; finger-tighten only –
do not use tools to tighten.
8.
Repeat
Step 5
NOTE: It is not necessary to connect all motors on a path to the same power supply
9.
Install a power bus end cap at the end of each power run to seal the cable; fin-
ger-tighten only – do not use tools to tighten.
10.
Bundle and dress all cables (use nylon cable-ties) as required to make sure of clean
cable routing.
11.
See
Facilities Connections on page 302
MagneMover LITE User Manual
4-61).
through
Step 7
for each motor in the power chain.
or to connect a power supply to only one path.
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Transport System Installation
Figure 4-60 on page 218
for external power connections.
Installation
275
Need help?
Do you have a question about the MagneMotion MagneMover LITE and is the answer not in the manual?
Questions and answers
Can you tell me if Puck part number 703-1207-00 Rev2 is still available. If not is Puck part number 703-1663-00-R2 capable / replacement for 703-1207-00-Rev2 Puck