Program Rs-422 Motors - Rockwell Automation MagneMotion MagneMover LITE Original Instructions Manual

Hide thumbs Also See for MagneMotion MagneMover LITE:
Table of Contents

Advertisement

Program RS-422 Motors

When a new RS-422 MagneMover LITE motor is installed, either as part of a new system
installation or as a replacement for an existing motor, it must be programmed with the appro-
priate Motor ERF Image file (motor_image.erf).
NOTE: MagneMover LITE motors are shipped from the factory with just a basic motor soft-
ware image installed. They must be programmed with the software that is supplied
with the motors before use.
Required Tools and Equipment
Computer with an Ethernet port and a web browser.
Motor ERF Image files.
Procedure
1.
Upload the Motor ERF Image files (motor_image.erf) to each node controller by using
the node controller web interface and program the motors. See the Node Controller
Interface User Manual, MMI-UM001, for details.
NOTE: Restart the node controller for the changes to take effect.
2.
Reset the paths where the motors were programmed (for example, use the NCHost
TCP Interface Utility, see the NCHost TCP Interface Utility User Manual,
MMI-UM010, for details).
MagneMover LITE User Manual
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Maintenance
Repair
387