Specifications and Site Requirements
Communication
connected. If a fifth connection to the status TCP/IP port is attempted, it causes the first status
connection to be disconnected.
The TCP/IP connection to all node controllers uses standard Ethernet network wiring. If mul-
tiple node controllers are connected to the same network, the IP address of each additional
node controller must be changed to a unique address to avoid IP conflicts. The TCP/IP address
that is used on the node controllers must be configured as specified in the Node Controller
Interface User Manual, MMI-UM001.
TCP/IP Communication – Node Controller to Motor
When using motors that support Ethernet communication, the NC-S, NC-E, NC-12, and NC
LITE node controllers are connected to the motors and switches in a network using standard
Cat 5 cable. The motors can use different network style connection schemes depending on the
application (see
When using Ethernet, all motors in a specific path must be connected to the same node con-
troller (see
Figure 3-10 on page 91
paths can be connected to the node controller using the same Ethernet chain. See
and
Figure 4-59
Node Controller Hardware Manual, MMI-UM013, for the locations of these connections on
the node controllers.
TCP/IP Communication – Motor to Motor
When using motors that support Ethernet communication, the motors are connected to each
other or the network, depending on the connection scheme being used (see
Connection Examples on page
nected to the same network, the IP address of each motor must be unique to avoid IP conflicts.
The TCP/IP address that is used on the motors must be configured as specified in
Motor Communication Recommendations on page
EtherNet/IP Communication – Host Controller to HLC
EtherNet/IP communication is supported for use when the host controller uses UDP-based
implicit messaging. EtherNet/IP communication allows the host controller to communicate
with the HLC as described in the Host Controller EtherNet/IP Communication Protocol User
Manual, MMI-UM004.
The connection from the host controller to the node controller that is configured as the HLC
uses standard Ethernet network wiring. The EtherNet/IP address that is used on the node con-
troller that is configured as the HLC must be configured as specified in the Node Controller
Interface User Manual, MMI-UM001.
230
Ethernet Motor Communication Recommendations on page
through
for the locations of these connections on the motors and switches. See the
91), using standard Cat 5 cable. If multiple motors are con-
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Figure 3-21 on page
95). Additionally, multiple
90.
90).
Figure 4-57
Ethernet Motor
Ethernet
MagneMotion

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MagneMotion MagneMover LITE and is the answer not in the manual?

Questions and answers

Andy Marshall
April 28, 2025

Can you tell me if Puck part number 703-1207-00 Rev2 is still available. If not is Puck part number 703-1663-00-R2 capable / replacement for 703-1207-00-Rev2 Puck

User image 680f72a78f63c

Table of Contents