Installation
Transport System Installation
Installation Overview – User-Supplied Mounting
The following sequence provides an overview of the installation of the MagneMover LITE
motors, switches, and other components on user equipment or a custom stand system.
NOTICE
1.
Assemble a complete section of the track, including guideway, motor mounts, and
stand.
2.
Prepare and level the section of the track where the motors are going to be mounted
(see
Leveling the MagneMover LITE on page
3.
Secure the track to the floor or other equipment as required (see
port System on page
4.
Install the motors and switches, make sure that the motors and guide rails are collinear
to each other and the tops of all motors are coplanar to each other. Tighten the
V-braces (see
and Switches on page
NOTE: If railless motors are being used, make sure that the motor bodies are collin-
5.
Install the power supplies, node controllers, network switches, and cables (see
ing Electronics on page
6.
Install magnet arrays on the vehicles and install the vehicles on the system (see
ing Magnet Arrays/Pucks on page
NOTE: Install vehicles (pucks) on captive closed loop systems before closing the
7.
Make all communication, network, and power connections (see
on page
8.
Assemble the next section of the system following
it to the previously installed section verifying that both sections are in the same plane
and level to each other.
9.
Continue assembling and installing sections of the track until the system is complete.
242
Make sure that the equipment or stand system for mounting
the MagneMover LITE motors and the motor mounting sur-
faces are properly grounded to safety ground (earth).
252).
Mounting Motors and Switches on page
258, and
ear to each other.
If motors are installed in a wash-down environment, it must not exceed IP65.
Make sure that there is sufficient space around the motor mounting surface
for all connectors and for the bend radius of all cables.
263).
loop to eliminate the need to remove a guide rail.
302).
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
251).
Verify Motor and Switch Installation on page
276).
Step 1
Securing the Trans-
256,
Align and Secure Motors
262).
Facilities Connections
through
Step 7
and connect
Install-
Install-
MagneMotion
Need help?
Do you have a question about the MagneMotion MagneMover LITE and is the answer not in the manual?
Questions and answers
Can you tell me if Puck part number 703-1207-00 Rev2 is still available. If not is Puck part number 703-1663-00-R2 capable / replacement for 703-1207-00-Rev2 Puck