5. For Mode, selected either:
Active-backup: Transmits data on only one of the bonded devices at a time. When the
n
active device fails, the next available device in the list is chosen. This mode provides for
fault tolerance.
Round-robin: Alternates between bonded devices to provide load balancing as well as
n
fault tolerance.
6. Click to expand Devices.
7. Add Ethernet devices:
a. For Add device, click 
b. For Device, select an Ethernet device to participate in the bond pool.
c. Repeat for each appropriate Ethernet device.
8. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Add a network bond:
(config)> add network bond name
(config network bond name)>
The new network bond is enabled by default. To disable:
(config network bond name)> enable false
(config network bond name)>
4. Set the mode:
(config network bond name)> mode value
(config network bond name)>