Configure Power Input Voltage - Digi TX54 User Manual

Hide thumbs Also See for TX54:
Table of Contents

Advertisement

System administration
Disabled—Disables the Power button entirely, so that neither the short- or long-press
n
actions will shut down the device.
5. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. At the config prompt, type:
(config)> system power button value
where value is one of:
normal—The default behavior, in which both short-press and long-press Power button
n
actions shut down the device.
forced_only—Disables the short-press behavior of the Power button. A long-press
n
action will still shut down the device.
disabled—Disables the Power button entirely, so that neither the short- or long-press
n
actions will shut down the device.
4. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
5. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure power input voltage

The TX54 device supports multiple power voltage levels, and can be configured to respond to various
ranges of power input.
Required configuration items
The required input voltage.
TX54 User Guide
Configure power input voltage
883

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tx64

Table of Contents