System administration
Deletes all user files including Python scripts.
n
Clears event and system log files.
n
Additionally, if the RESET button is used to erase the configuration, pressing the RESET button a
second time immediately after the device has rebooted:
Erases all automatically generated certificates and keys.
n
With firmware release 22.2.9.x and newer, erases the client-side certificate used for
n
communication with Digi Remote Manager.
If you are using Digi Remote Manager with firmware release 22.2.9.x and newer, by default the
device uses a client-side certificate for communication with Remote Manager. If the client-side
certificate is erased, you must use the Remote Manager interface to reset the certificate.
You can also reset the device to the default configuration without removing scripts, keys, and logfiles
by using the revert command.
WebUI
1. Log into the TX54 WebUI as a user with Admin access.
2. On the main menu, click System. Under Configuration, click Configuration Maintenance.
The Configuration Maintenance windows is displayed.
3. In the Erase configuration section, click ERASE.
4. Click CONFIRM.
5. After resetting the device:
a. Connect to the TX54 by using the serial port or by using an Ethernet cable to connect the
TX54 LAN1 port to your PC.
TX54 User Guide
Erase device configuration and reset to factory defaults
876