Diagnostics
7. Enable Preserve system logs to save the current session's system log after a reboot.
By default, the TX54 device erases system logs each time the device is powered off or
rebooted.
Note
You should only enable Preserve system logs temporarily to debug issues. Once you are
finished debugging, immediately disable Preserve system logs to avoid unnecessary wear to
the flash memory.
8. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. (Optional) To change the heartbeat interval from the default of 30 minutes, set a new value.
The heartbeat interval determines the amount of time to wait before sending a heartbeat
event if no other events have been sent.
(config)> system log heartbeat_interval value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the format
number{w|d|h|m|s}.
For example, to set the heartbeat interval to ten minutes, enter either 10m or 600s:
(config)> system log heartbeat_interval 600s
(config)>
To disable the heartbeat interval, set the value to 0s
4. Enable preserve system logs functionality to save the current session's system log after a
reboot. By default, the TX54 device erases system logs each time the device is powered off or
rebooted.
Note
You should only enable Preserve system logs temporarily to debug issues. Once you are
finished debugging, immediately disable Preserve system logs to avoid unnecessary wear to
the flash memory.