Digi TX54 User Manual page 946

Hide thumbs Also See for TX54:
Table of Contents

Advertisement

Central management
3. Click Monitoring > Device Health.
4. (Optional) Click to expand Data point tuning.
Data point tuning options allow to you configure what data are uploaded to the Digi Remote
Manager. All options are enabled by default.
5. Only report changed values to Digi Remote Manager is enabled by default.
When enabled:
The device only reports device health metrics that have changed health metrics were
n
last uploaded. This is useful to reduce the bandwidth used to report health metrics.
All metrics are uploaded once every hour.
n
When disabled, all metrics are uploaded every Health sample interval.
6. Device health data upload is enabled by default. To disable, click to toggle off Enable Device
Health samples upload.
7. For Health sample interval, select the interval between health sample uploads.
8. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Device health data upload is enabled by default. To enable or disable:
To enable:
n
(config)> monitoring devicehealth enable true
(config)>
To disable:
n
(config)> monitoring devicehealth enable false
(config)>
TX54 User Guide
Collect device health data and set the sample interval
946