Monitoring
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Enable the Bluetooth scanner:
(config> monitoring bluetooth_scanner enable true
(config)>
4. (Optional) Set the number of seconds between scans:
(config)> monitoring bluetooth_scanner update_interval value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the format
number{w|d|h|m|s}.
For example, to set update_interval to ten minutes, enter either 10m or 600s:
(config)> monitoring bluetooth_scanner update_interval 600s
(config)>
The minimum value is 5 seconds, and the default is 15 seconds.
5. Enable the device to open an SSH port that remote hosts can access:
(config> monitoring bluetooth_scanner ssh enable true
(config)>
6. (Optional) Set the number of the port that the Bluetooth scanner will use. The default is 3102.
(config)> monitoring bluetooth_scanner ssh port port
(config)>
7. Configure access control:
To limit access to specified IPv4 addresses and networks:
n
(config)> add monitoring bluetooth_scanner ssh acl address end value
(config)>
Where value can be:
l
l
l
Repeat this step to list additional IP addresses or networks.
To limit access to specified IPv6 addresses and networks:
n
(config)> add monitoring bluetooth_scanner ssh acl address6 end
value
(config)>
Where value can be:
TX54 User Guide
A single IP address or host name.
A network designation in CIDR notation, for example, 192.168.1.0/24.
any: No limit to IPv4 addresses that can access the SSH service.
Enable the Bluetooth scanner