System administration
  WebUI
1. Log into the TX54 WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
3. Click System > Power.
4. For Power voltage control, select one of the following options:
12
n
l
l
24
n
l
l
9-36
n
l
l
5. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the TX54 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
TX54 User Guide
Powers up if input power is above 11.5 volts.
Powers down if input power drops below 10.5 volts.
Powers up if the input power is above 23 volts.
Powers down if the power drops below 21 volts.
Powers up if the input power is above 8.5 volts.
Powers down if the input power drops below 8 volts.
Configure power input voltage