Temporarily Set The Ignition Power Delay; Configure Automatic Reboot Behavior For Temporary Power Drop - Digi TX54 User Manual

Hide thumbs Also See for TX54:
Table of Contents

Advertisement

System administration

Temporarily set the ignition power delay

By default, the TX54 device automatically powers on when it detects power on the ignition sensor,
and powers off when it detects that there is no power on the ignition sensor.
You can temporarily set the device's ignition power off delay without changing the device
configuration by using the
maintenance activities, such as a firmware update, to occur after the ignition is switched off.
Once the device has powered off, the temporary power off delay will no longer apply and the device
will use the previously configured power off delay when it restarts.
  Command line
1. Log into the TX54 command line as a user with Admin access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. To temporarily override the configured ignition power on delay:
> system power ignition off_delay OFF_DELAY
where OFF_DELAY is any number of hours, minutes, or seconds, and takes the format number
{h|m|s}.
For example, to set the ignition power on delay to ten minutes, enter either 10m or 600s:
(config)> system power ignition on_delay 600s
(config)>
The maximum value is 18h.
3. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure automatic reboot behavior for temporary power drop

By default, the TX54 device will automatically reboot if the ignition sense line is high and the device
experiences a temporary power drop.
To disable the automatic reboot behavior:
  WebUI
1. Log into the TX54 WebUI as a user with full Admin access rights.
2. On the menu, click System. Under Configuration, click Device Configuration.
The Configuration window is displayed.
TX54 User Guide
system power ignition off_delay
Power ignition sensor
command. This allows for one-time
888

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tx64

Table of Contents