Appendix D Installation in the SAN Boot Environment
D.4.3
Setting up the FC switch
The FC switches for the ETERNUS SN200 series are generally set up through a
connection to the OS of the ETERNUS SN200 series machine from a telnet terminal
(an ordinary PC can be used).
In the rest of this section, a switch means an FC switch.
1
Preparation for switch setup
Check the WWPNs of the ETERNUS unit and HBA.
Obtain the WWPN of the ETERNUS unit by using ETERNUSmgr and selecting
the WWPN list function from the menu for displaying the unit status. The list
function lists the WWPNs assigned to CAs. For details, see the ETERNUS
manuals.
For details on how to obtain the WWPN of the HBA, see
"Configuring the EFI driver."
2
Basic switch settings
The IP addresses in the LAN, subnet masks, and the gateway addresses of the
switch and PC must be set. These switch settings can be made from the operation
panel or through the serial port. For details, see the reference manuals for the
ETERNUS SN200 series.
The setting that activates the switch SNMP function must also be made. If zoning
is already set up for the switch, however, this is not required.
3
Zone creation, configuration creation, and configuration validation
Create and validate zones and the related configuration. For details on these
operations, see the ETERNUS user's guide.
D-6
Section D.4.4,
C122-E001-10EN