Fujitsu PRIMEQUEST 1000 Series Installation Manual
Fujitsu PRIMEQUEST 1000 Series Installation Manual

Fujitsu PRIMEQUEST 1000 Series Installation Manual

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

Quick Links

FUJITSU Server
PRIMEQUEST 1000 Series

Installation Manual

C122-E107-09EN

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMEQUEST 1000 Series

  • Page 1: Installation Manual

    FUJITSU Server PRIMEQUEST 1000 Series Installation Manual C122-E107-09EN...
  • Page 3: How To Use This Manual

    Be sure to keep this manual in a safe and convenient location for quick reference. Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage. Be sure to use the product according to the instructions in the manual.
  • Page 4 CHAPTER 8 Powering On and Off a Partition Chapter 7 describes partition power control. APPENDIX A Lists of Settings (Links) Appendix A provides links to Appendix A List of Settings in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). APPENDIX B Manual PSA Installation and Uninstallation Appendix B describes how to manually install and uninstall PSA for a specific operating system.
  • Page 5 The index lists keywords and the pages that they refer to, helping readers quickly find the necessary information in the manual. Manuals for the PRIMEQUEST 1000 series The following manuals have been prepared to provide you with the information necessary to use the PRIMEQUEST 1000 series.
  • Page 6 Related manuals The following manuals relate to the PRIMEQUEST 1000 series. You can access these manuals at the following site: http://jp.fujitsu.com/platform/server/primequest/manual-e/ Contact your sales representative for inquiries about the ServerView manuals.
  • Page 7 PRIMEQUEST 1000 Series Installation Manual Preface Title Description Manual code ServerView Suite Describes RAID management using ServerView None ServerView RAID RAID Manager. Management User Manual ServerView Suite Describes the basic concepts of ServerView None Basic Concepts Suite. ServerView Operations Describes installation and update installation of...
  • Page 8 PRIMEQUEST 1000 Series Installation Manual Preface Title Description Manual code Refer to the manual from the SVS-DVD2 supplied with the product or from the following URL: The Fujitsu Technology Solutions manuals server http://manuals.ts.fujitsu.com/ Abbreviations This manual uses the following product name abbreviations.
  • Page 9 PRIMEQUEST 1000 Series Installation Manual Preface Formal product name Abbreviation VMware vSphere(R) 4 VMware, vSphere 4.x, VMware 4.x VMware vSphere(R) 5 VMware, vSphere 5.x, VMware 5.x VMware(R) ESX(R) 4 ESX, ESX 4.x VMware(R) ESXi(TM) 5 ESXi, ESXi 5.x Novell(R) SUSE(R) LINUX Enterprise Server 11 Service Pack 2...
  • Page 10: Alert Messages

    Similarly, one space line is inserted before and after the alert statement. Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu. Customers must not perform these tasks under any circumstances. Otherwise, electric shock, injury, or fire may result.
  • Page 11 PRIMEQUEST 1000 Series Installation Manual Preface - Linux is a registered trademark of Linus Torvalds. - Red Hat, the Shadowman logo and JBoss are registered trademarks of Red Hat, Inc. in the U.S. and other countries. - Intel and Xeon are trademarks or registered trademarks of Intel Corporation.
  • Page 12 PRIMEQUEST 1000 Series Installation Manual Preface Work Warning Location category Normal The unit may be damaged or operating abnormally. 2.1 Safety operation - Follow the precautions, warnings, and instructions shown on the Precautions main unit. - Do not block the vent holes.
  • Page 13: Warning Labels

    PRIMEQUEST 1000 Series Installation Manual Preface Work Warning Location category Normal (Damage to data) 3.2.1 Powering operation Confirm that the System Power LED of the DVDB is off before turning off on and off the the main power (e.g., UPS, power distribution box). If you turn off the main main unit power (e.g., UPS, power distribution box) while the System Power LED...
  • Page 14 PRIMEQUEST 1000 Series Installation Manual Preface Warning label location (PRIMEQUEST 1800E2/1800E rear) (IOBs removed) Warning label location (PCI_Box) C122-E107-09EN...
  • Page 15 Notes on Handling the Product Adding optional products For stable operation of the PRIMEQUEST 1000 series server, use only a Fujitsu certified optional product as an added option. Note that the PRIMEQUEST 1000 series server is not guaranteed to operate with any optional product not certified by Fujitsu.
  • Page 16: Support And Service

    Product and service inquiries For all product use and technical inquiries, contact the distributor where you purchased your product, or a Fujitsu sales representative or systems engineer (SE). If you do not know the appropriate contact address for inquiries about the PRIMEQUEST 1000 series, use the Fujitsu contact line.
  • Page 17 PRIMEQUEST 1000 Series Installation Manual Preface Edition Date Revised location (type) (*) Description Incorporated differences in Errata and 2010-08-20 All pages Addenda (C122-E119-02EN to C122- E119-10EN) - Added items about 1800E2 - Incorporated differences in Errata and Addenda (C122- E119-11EN to C122-...
  • Page 18 However, a number marked with an asterisk (*) denotes a chapter, section, or item in a previous edition of the document. This manual shall not be reproduced or copied without the permission of Fujitsu Limited. Copyright 2010 - 2012 FUJITSU LIMITED...
  • Page 19: Table Of Contents

    PRIMEQUEST 1000 Series Installation Manual Contents Contents CHAPTER 1 Installation Overview ........................1 1.1 Setup Workflow ............................2 1.1.1 Work performed by a field engineer ....................2 1.1.2 Work performed by the user ........................ 2 CHAPTER 2 Preparing for Main Unit Installation ....................
  • Page 20 PRIMEQUEST 1000 Series Installation Manual Contents 4.2.4 Configuring bundled software after the completion of installation ............. 64 4.2.5 Connecting the SAN and built-in HDD after the installation .............. 66 4.3 RHEL Installation Procedures on the Built-in HDD .................. 67 4.3.1 Advance setup ...........................
  • Page 21 PRIMEQUEST 1000 Series Installation Manual Contents 4.11.1 Advance setup ..........................110 4.11.2 Preparing for Installation ....................... 110 4.11.3 Installing the operating system ..................... 110 4.11.4 Configuring bundled software after the completion of installation ..........113 4.11.5 Connecting the SAN and built-in HDD after the installation ............
  • Page 22 CHAPTER 7 Work after Installation ....................... 205 7.1 Duplicate Network Adapter Configuration ..................... 206 7.2 Configuring NTP ........................... 207 7.2.1 How NTP operates in the PRIMEQUEST 1000 series ..............207 7.2.2 Setting an NTP server ........................208 7.3 Configuring a DNS Server ........................211 7.4 Configuring SMTP...
  • Page 23 PRIMEQUEST 1000 Series Installation Manual Contents APPENDIX C Software (Links) ........................257 C.1 General Description and Types of Bundled Software ................258 APPENDIX D Configuring the SAN Boot Environment .................. 259 APPENDIX E Notes on VMware Installation ....................260 E.1 Building a RAID Environment Using VMware 4.x Built-in Disks ............
  • Page 24 PRIMEQUEST 1000 Series Installation Manual Figures Figures Warning label location (PRIMEQUEST 1800E2/1800E rear) ................xi Warning label location (PRIMEQUEST 1800E2/1800E rear) (IOBs removed) ..........xii Warning label location (PCI_Box) ........................xii FIGURE 2.1 Power cable socket locations (PRIMEQUEST 1800E2/1800E) ..........15 FIGURE 2.2 Power cable socket locations (PCI_Box)
  • Page 25 PRIMEQUEST 1000 Series Installation Manual Figures FIGURE 6.2 [Add a Port] dialog box (SNMP) ....................157 FIGURE 6.3 Preparing to Install window ....................... 159 FIGURE 6.4 Update installation window ......................160 FIGURE 6.5 Update installation complete window ..................161 FIGURE 6.6 Confirmation message dialog box .....................
  • Page 26 PRIMEQUEST 1000 Series Installation Manual Figures FIGURE E.4 [Software Watchdog] window ....................264 FIGURE E.5 Network configuration immediately after installation of OS ............271 FIGURE E.6 Network configuration after setup ..................... 276 FIGURE E.7 VMware vSphere 4.x Client ...................... 277 FIGURE E.8 [DNS and Routing Configuration] dialog box...
  • Page 27 PRIMEQUEST 1000 Series Installation Manual Tables Tables TABLE 1.1 Work performed by the user ......................2 TABLE 2.1 Accessories required in main unit installation ................11 TABLE 3.1 MMB connection and configuration flow ..................20 TABLE 3.2 External interfaces of the MMB .....................
  • Page 28 PRIMEQUEST 1000 Series Installation Manual Tables TABLE B.4 Settings automatically added/changed during PSA installation ..........237 TABLE E.1 Settings after PSA Installation (VMware 4.x) ................270 TABLE E.2 IP addresses to be set for virtual ports ..................275 TABLE E.3 Configuring the firewall for PSA operation ..................
  • Page 29: Chapter 1 Installation Overview

    This chapter describes the workflow up to actual operation of the PRIMEQUEST 1000 series server. For an overview of the hardware and software and the part names and functions of the server, see the PRIMEQUEST 1000 Series General Description (C122-B022EN). 1.1 Setup Workflow...
  • Page 30: Setup Workflow

    CHAPTER 1 Installation Overview Setup Workflow This section describes the workflow for the tasks required to prepare the PRIMEQUEST 1000 series server for operation. Setup work consists of tasks performed by a field engineer and other tasks performed by the user.
  • Page 31 PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview Work item Work tasks and description - Initializing MMB settings 3.3.10 Registering a user Set the parameters for the entire MMB, such as account the user account names or system names.
  • Page 32 PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview C122-E107-09EN...
  • Page 33: Chapter 2 Preparing For Main Unit Installation

    CHAPTER 2 Preparing for Main Unit Installation This chapter describes the preparation before main unit installation. This preparation includes work up to power cable connection. 2.1 Safety Precautions ............6 2.2 Before Installing the Main Unit ........7 2.3 Checking Environmental Conditions ......
  • Page 34: Safety Precautions

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation Safety Precautions Observe the following precautions when installing the main unit. Failure to do so cause damage to the unit or abnormal operation. - Follow the precautions, warnings, and instructions shown on the main unit.
  • Page 35: Before Installing The Main Unit

    Be sure that you understand the system configuration and have acquired all the requisite installation information before installing the main unit. For a system overview and details on the system configuration, see the PRIMEQUEST 1000 Series General Description (C122-B022EN). For details on the installation prerequisites, see the PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN).
  • Page 36: Checking Environmental Conditions

    The conditions of the main unit operating environment depend on the altitude at the installation site. For details on the environmental conditions of the PRIMEQUEST 1000 series, see 1.3 Installation Specifications in the PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN).
  • Page 37: Preparing The Power Supply Equipment

    2.2.2 Basic interfaces and peripheral devices (PRIMEQUEST 1800E) in the PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN). For details on the connectors and their shapes, see 2.4.1 PRIMEQUEST 1000 series main unit in the PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN).
  • Page 38: Checking The Installation Site

    Before installing the main unit, confirm that the installation site has enough space for the required service (maintenance) area and for accommodating the peripheral devices. For details on checks of the installation site, see Chapter 1 Installation Information in the PRIMEQUEST 1000 Series Hardware Installation Manual (C122- H004EN).
  • Page 39: Preparing To Install The Main Unit

    Ethernet Category 5 cable or better representative. Console PC-to-LAN cable (for user LAN) External switching hub Used to connect the PRIMEQUEST 1000 series server to an external switching hub via a LAN. Multitester Used to check the input AC voltage. C122-E107-09EN...
  • Page 40: Confirming The Supplied Parts

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation Confirming the Supplied Parts Confirm that the supplied parts match the shipping list provided with the main unit. If any of the parts listed in the shipping list or performance records are missing, incorrect, or damaged, contact the distributor where you purchased your product, or your sales representative.
  • Page 41: Mounting The Main Unit In A 19-Inch Rack

    CHAPTER 2 Preparing for Main Unit Installation Mounting the Main Unit in a 19-inch Rack The PRIMEQUEST 1000 series server is mounted for use in a 19-inch rack. For details on mounting, see Appendix A Racks in the PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN).
  • Page 42: Connecting The Power Cables

    Operations 1. Confirm with an on-site electrical engineer that the input power satisfies power requirements. For details on the power requirements, see 1.3 Installation Specifications in the PRIMEQUEST 1000 Series Hardware Installation Manual (C122-H004EN). 2. Confirm that the power cables are connected to the AC inlets of the main unit and PCI_Box. Also confirm that the power cables are secured with the AC cord clamps for the AC inlets on the main unit.
  • Page 43: Figure 2.1 Power Cable Socket Locations (Primequest 1800E2/1800E)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation FIGURE 2.1 Power cable socket locations (PRIMEQUEST 1800E2/1800E) FIGURE 2.2 Power cable socket locations (PCI_Box) C122-E107-09EN...
  • Page 44 PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation C122-E107-09EN...
  • Page 45: Chapter 3 Work Before Operating System Installation

    Work before Operating System Installation This chapter describes the work that must be done before you install an operating system on the PRIMEQUEST 1000 series server. The chapter also describes the settings required for practical operation and the necessary setup work.
  • Page 46: Before Starting Setup

    - IP address of the PC used as the MMB console (referred to below as the MMB console PC) - User accounts - Name of the PRIMEQUEST 1000 series system (also used as the SNMP system name) - Management LAN environment ... etc.
  • Page 47: Starting The System

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation Starting the System This section describes power control for system startup. Use the following power-on procedure only when the power to the main unit is off. 3.2.1 Powering on and off the main unit This section describes how to power on and power off the main unit.
  • Page 48: Connecting And Configuring The Mmb

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation Connecting and Configuring the MMB A field engineer will have constructed a test environment for the MMB to run test programs in it. Therefore, you need to reconfigure the MMB to switch from the test environment to that for actual operation. Skip the steps for items already set by the field engineer.
  • Page 49: Connecting The Mmb Console Pc

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation All screenshots are display examples, and the actually displayed contents vary depending on the system configuration and other factors. 3.3.1 Connecting the MMB console PC This section describes how to connect the MMB console PC.
  • Page 50: Initializing Mmb Settings

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation Setting item Value Data bit Parity None Stop bit Flow control None Emulation VT100 3.3.2 Initializing MMB settings The procedure for initializing MMB settings is as follows. If the field engineer has already made the settings, you can skip the following procedure.
  • Page 51: Setting Up The Connection Environment For Actual Operation

    Connecting the PRIMEQUEST 1000 series server to an external LAN The following describes the configuration of external LAN connections of the PRIMEQUEST 1000 series server. It also describes points to consider about the connections. We recommend you configure security before connecting an external LAN.
  • Page 52: Figure 3.3 Network Configuration And Ip Addresses Of The Management Lan

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation FIGURE 3.3 Network configuration and IP addresses of the management LAN Connect the management (USER) ports of MMB#0 and MMB#1 to an external switching hub with LAN cables.
  • Page 53: Logging In To The Mmb

    - Do not attempt multiple logins (e.g., multiple logins with the same user name) from one MMB console PC through the Web-UI to the PRIMEQUEST 1000 series system. Multiple logins may cause the following problems, depending on the browser type or version. In a tabbed browser, avoid using multiple tabs for one login session, which would be the same as multiple logins.
  • Page 54: Figure 3.4 Mmb Web-Ui Login Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation Enable JavaScript and enable Download in your browser settings. 2. Enter the following URL. TABLE 3.5 URL to enter for login Standard http://nodename:adminport http://nodename:adminport/login.cgi (Windows Server 2008 and Windows...
  • Page 55: How To View The Web-Ui Window

    If the Web-UI window displays "Read Error," check for details on the error in 11.2 Troubleshooting in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). If you cannot solve the problem even after referring to the manual, contact your sales representative or a field engineer.
  • Page 56: Figure 3.6 Maintenance Status Display

    Serial Number This field displays the serial number of the PRIMEQUEST 1000 series server. Status This field displays the status of the entire PRIMEQUEST 1000 series system. The following table shows the three system status indicators. TABLE 3.7 System status indicators...
  • Page 57: Figure 3.7 Submenu Area

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation The selected menu is displayed in black characters. The menus not selected are displayed in white characters. Logout Click here to log out from the Web-UI. Submenu breadcrumb trail This bar displays each level on the path to the menu that is displayed in the submenu area.
  • Page 58: Figure 3.8 Content Area

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation - Placing the cursor on a submenu highlights the submenu. - The selected submenu has a different background color. - The background colors of menus at different levels depend on the level.
  • Page 59: Table 3.8 Buttons In The Title Area

    Input fields, radio buttons, and check boxes are grayed out and unavailable if authenticated users do not have corresponding privileges. For details on the privileges, see TABLE 1.1 User privileges in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). Button area This area displays buttons for setting the contents of the status display and settings area.
  • Page 60: Configuring The Mmb Network

    Remarks Once the virtual IP address is set: Web browsers have access through the virtual IP address of the PRIMEQUEST 1000 series server. They cannot access the MMB Web-UI through the specified physical IP address of MMB#0 or MMB#1. The maintenance terminal and REMCS has access through the address specified in [Maintenance IP Address]. You can specify the address by selecting [Network Configuration] - [Network Interface].
  • Page 61: Configuring Telnet

    1. Click [Network Configuration] - [Network Interface]. >> The [Network Interface] window appears. For details on the [Network Interface] window, see 1.5.2 [Network Interface] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.9 [Network Interface] window (example) 2. Enter values in [IP Address], [Subnet Mask], and [Gateway Address] in [Virtual IP Address]. Also specify the host name.
  • Page 62: Configuring A Dns Server

    1. Click [Network Configuration] - [Network Protocols]. >> The [Network Protocols] window appears. For details on the [Network Protocols] window, see 1.5.4 [Network Protocols] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.10 [Network Protocols] window (example) 2. Specify each item in [Telnet].
  • Page 63: Configuring Alarm E-Mail

    CHAPTER 3 Work before Operating System Installation >> The [Network Interface] window appears. For details on the [Network Interface] window, see 1.5.2 [Network Interface] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.11 [Network Interface] window (example) 2. Click [Enable] for [DNS] in [DNS(optional)]. Then, enter a value for each item.
  • Page 64: Figure 3.12 [Alarm E-Mail] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation FIGURE 3.12 [Alarm E-Mail] window (example) 2. Enter values in the required fields. Remarks - As described below, the [From] address is sent with Alarm E-Mail notification to the SMTP server: - If the [Use envelope "from"...
  • Page 65: Registering A User Account

    CHAPTER 3 Work before Operating System Installation >> The [Alarm E-Mail Filtering Condition] window appears. For details on the [Alarm E-Mail Filtering Condition] window, see [Alarm E-Mail Filtering Condition] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.13 [Alarm E-Mail Filtering Condition] window (example) 2.
  • Page 66: Figure 3.14 [User List] Window (Example)

    2. Click the [Add User] button. >> The [Add User] window appears. For details on the [Add User] window, see the part about the [Add User] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.15 [Add User] window (example)
  • Page 67: Setting The System Name

    4. Click the [Apply] button. 3.3.11 Setting the system name Specify a name for the PRIMEQUEST 1000 series system. This name is also used as the SNMP system name. For details on how to back up the specified information, see 3.5 Saving Configuration Information.
  • Page 68: Setting The Date And Time

    NTP server as reference. For stable NTP operation, specify multiple NTP servers (at least three servers in RHEL) from each NTP client. Operations in the [Date/Time] window 1. Click [Network Configuration] - [Date/Time]. >> The [Date/Time] window appears. For details on the [Date/Time] window, see 1.5.1 [Date/Time] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 69: Figure 3.18 [Date/Time] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation FIGURE 3.18 [Date/Time] window (example) 2. Enter values in the required fields. 3. Click the [Apply] button. Operations in the [Management LAN Port Configuration] window 1. Click [Network Configuration] - [Management LAN Port Configuration].
  • Page 70: Figure 3.19 [Management Lan Port Configuration] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation FIGURE 3.19 [Management LAN Port Configuration] window (example) 2. Enter values in the required fields. 3. Click the [Apply] button. C122-E107-09EN...
  • Page 71: Configuring A Partition

    Operations 1. Click [Partition] - [Partition Configuration]. >> The [Partition Configuration] window appears. For details on the [Partition Configuration] window, see 1.3.4 [Partition Configuration] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.20 [Partition Configuration] window (example) Remarks The above window shows the maximum configuration.
  • Page 72: Figure 3.21 [Add Sb/Iob/Gspb To Partition] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation Partition] window in 1.3.4 [Partition Configuration] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.21 [Add SB/IOB/GSPB to Partition] window (example) 4. Click the radio button of an SB, IOB, or GSPB to add it to the partition.
  • Page 73: Figure 3.22 [Partition Configuration] Window (Example)

    GSPBs. These SBs IOBs, and GSPBs are incorporated in the partition selected in step 2. For details on the [Remove SB/IOB/GSPB from Partition] window, see [Remove SB/IOB/GSPB from Partition] window in 1.3.4 [Partition Configuration] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 74: Setting A Home Sb

    You can use the USB port and VGA port as external connectors of the Home SB. If you want to change the Home SB, specify the change with the Web-UI. For details on the Home SB, see 5.2.4 Home SB in the PRIMEQUEST 1000 Series General Description (C122-B022EN). Remarks Windows license verification may be required depending on the combination of the SB and enable kit.
  • Page 75: Setting A Reserved Sb

    CHAPTER 3 Work before Operating System Installation >> The [Partition Home] window appears. For details on the [Partition Home] window, see [Partition Home] window in 1.3.4 [Partition Configuration] window in the PRIMEQUEST 1000 Series Tool Reference (C122- E110EN). FIGURE 3.24 [Partition Home] window (example) 2.
  • Page 76: Figure 3.25 [Reserved Sb Configuration] Window (Example)

    - Free SBs - SBs incorporated in other partitions - SBs defined as the Reserved SBs of other partitions For details on the Reserved SB, see 3.2.1 Reserved SB in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). Remarks Windows license verification may be required depending on the combination of the SB and enable kit. For details, see "License authentication with SB and enable kit combinations"...
  • Page 77 However, the following workaround can suppress the restart request. Workaround for the Windows restart You can suppress the restart request only if the PRIMEQUEST 1000 series server has already set as the Reserved Repeat the following procedure for all the partitions with Windows Server OS installed.
  • Page 78: Figure 3.26 Bluescreentimeout Setting ([Configuration] Tab)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation 5. Log in with Administrator privilege. After the message that the system must be restarted is displayed on the screen, follow the instructions to restart the system. 6. After the Windows restart is completed, shut down the system.
  • Page 79: Setting A Partition Name

    If the specified name is the same as the specified host name of the operating system, the partition is easy to recognize. Operations 1. Click [Partition] - [Partition Configuration]. >> The [Partition Configuration] window appears. For details on the [Partition Configuration] window, see 1.3.4 [Partition Configuration] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 80: Setting Various Modes

    Set Mirror mode, Hyper Threading mode, and other modes for the partition. The MMB Web-UI and UEFI (Unified Extensible Firmware Interface) windows have settings items for these settings. The following table lists the setting items and the screen transitions. For details on each setting, see the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN).
  • Page 81 FC card to be used for the installation. - Confirm that the Boot device to be used in the relevant partition has been recognized by the UEFI. For details on this confirmation, see 5.4 [Boot Manager] Menu in the PRIMEQUEST 1000 Series Tool Reference (C122- C122-E107-09EN...
  • Page 82: Figure 3.29 [Mode] Window (Example)

    Operations 1. Click [Partition] - [Partition#x] - [Mode]. >> The [Mode] window appears. For details on the [Mode] window, see [Mode] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.29 [Mode] window (example) Remarks The window displays the [PSA] menu only in the PRIMEQUEST 1800E.
  • Page 83: Configuring Console Redirection

    1. Click [Partition] - [Console Redirection Setup]. >> The [Console Redirection Setup] window appears. For details on this window, see 1.3.6 [Console Redirection Setup] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 3.30 [Console Redirection Setup] window (example) 2.
  • Page 84: Checking Partition Information

    Checking partition information Check partition information by displaying the partition status and partition-related information. You can also check the partition configuration of the entire PRIMEQUEST 1000 series system in the [Partition Configuration] window. Operations 1. Click [Partition] - [Partition#x] - [Information].
  • Page 85: Saving Configuration Information

    This section describes how to back up MMB configuration information. Remarks For details on how to restore MMB configuration information, see 8.1.2 Backing up and restoring MMB configuration information in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). Operations 1. Click [Maintenance] - [Backup/Restore Configuration] - [Backup/Restore MMB Configuration].
  • Page 86 PRIMEQUEST 1000 Series Installation Manual CHAPTER 3 Work before Operating System Installation >> The save destination dialog box of the browser appears. 3. Select the save destination path. Then, click the [OK] button. >> Download of the configuration information file begins.
  • Page 87: Chapter 4 Installing The Operating System And Bundled Software

    CHAPTER 4 Installing the Operating System and Bundled Software This appendix describes the procedures for installing RHEL, Windows, and VMware on the SAN storage unit or built-in HDD. For details on the installation procedures, see the respective references. 4.1 Installation Procedure for the Operating System and Bundled Software ..........
  • Page 88: Installation Procedure For The Operating System And Bundled Software

    For details, see G.1 CPU in the PRIMEQUEST 1000 Series Administration Manual (C122- E108EN). Use SVIM to install the operating system on a partition of the PRIMEQUEST 1000 series server. SVIM is a setup support tool for the following operations:...
  • Page 89: Rhel Installation Procedures On The San Storage Unit

    For details on I/O space assignment, see 3.4.5 Setting various modes in this manual and 5.5.1 [Configure I/ O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.2.2 Preparing for Installation No RHEL distribution DVD is available for RHEL installation. Users who have purchased a RHEL subscription will need to create a RHEL distribution DVD.
  • Page 90: Installing The Operating System

    Operations 1. Make the setting for booting the partition from remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 91: Figure 4.1 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 92: Configuring Bundled Software After The Completion Of Installation

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software Remark The IP address of the LAN cannot be set through the operating system setup. Set the IP address after the installation of the operating system.
  • Page 93 The downloaded binary file has a description about the PRIMERGY, but the driver and utility can be used for the PRIMEQUEST 1000 series. 3. Copy the downloaded file to an arbitrary directory of the PRIMEQUEST 1000 series, and then expand # tar xvzf F1010350.tar.gz 4.
  • Page 94: Connecting The San And Built-In Hdd After The Installation

    4.2.5 Connecting the SAN and built-in HDD after the installation For details on connecting the SAN and built-in HDD after the installation, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN). Also, for details ondriver parameters, see the readme file that comes with the driver.
  • Page 95: Rhel Installation Procedures On The Built-In Hdd

    For details on I/O space assignment, see 3.4.5 Setting various modes in this manual and 5.5.1 [Configure I/ O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.3.2 Preparing for Installation No RHEL distribution DVD is available for RHEL installation. Users who have purchased a RHEL subscription will need to create a RHEL distribution DVD.
  • Page 96: Installing The Operating System

    2. Mount the disk image of the RHEL distribution DVD on remote storage. 3. Change the boot order to give the highest priority to booting the storage unit where the operating system is installed. For details, see 1.3.1 [Power Control] window in the PRIMEQUEST 1000 Series Tool Reference (C122- E110EN). 4.3.3 Installing the operating system This section describes the operating system installation with SVIM.
  • Page 97: Figure 4.2 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 98: Configuring Bundled Software After The Completion Of Installation

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software Remark The IP address of the LAN cannot be set through the operating system setup. Set the IP address after the installation of the operating system.
  • Page 99 The downloaded binary file has a description about the PRIMERGY, but the driver and utility can be used for the PRIMEQUEST 1000 series. 3. Copy the downloaded file to an arbitrary directory of the PRIMEQUEST 1000 series, and then expand # tar xvzf F1010350.tar.gz 4.
  • Page 100: Connecting The San And Built-In Hdd After The Installation

    4.3.5 Connecting the SAN and built-in HDD after the installation For connecting the SAN and built-in HDD after the installation, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN). Also, for details on driver parameters, see the readme file that comes with the driver.
  • Page 101: Windows Installation Procedures On The San Storage Unit

    SAS controller (GSPB), SAS disk unit controller and SAS array disk unit controller. For details on I/O space assignment, see 3.4.5 Setting various modes in this manual and 5.5.1 [Configure I/ O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.4.2 Preparing for Installation Prepare the following.
  • Page 102: Table 4.3 Operating System Installation By Svim

    Operations 1. Make the setting for booting the partition from remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 103: Figure 4.3 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 104: Figure 4.4 [Mode] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software 8. Replace the media with the operating system installation media according to the SVIM instructions. 9. Perform the following operation by using the MMB Web-UI. Remarks These steps are not required in Windows Server 2012.
  • Page 105: Figure 4.5 [Install Windows] Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software FIGURE 4.5 [Install Windows] window 2. When the [Install Windows] window appears after a system reboot following termination of the [Installing updates] window with the [Install Windows] window displayed as is in 1. above.
  • Page 106: Configuring Bundled Software After The Completion Of Installation

    Note The downloaded binary file has a description about the PRIMERGY, but the driver and utility can be used for the PRIMEQUEST 1000 series. 2. Execute the downloaded file by double-clicking it. The prompt screen for the cmd.exe (a window with a black background) is displayed for a while, and then the file is extracted.
  • Page 107: Table 4.4 If The Folder Contains Two Files

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software 2. Double-click the file in the <DVD drive name>:\HotFixes\SR-IO folder to run it. - If the folder contains the following two files, select a file according to the Windows type.
  • Page 108 12. Configure the dump area. Confirm that the hard disk has enough free space before collecting a memory dump. For details, see 11.4.4 Setting up the dump environment (Windows) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 13. Configure the NTP client.
  • Page 109: Connecting The San And Built-In Hdd After The Installation

    4.4.5 Connecting the SAN and built-in HDD after the installation For details on connecting the SAN and built-in HDD after the installation, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN). 1. Change and check the setting of detailed FC card information. For details, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN).
  • Page 110: Windows Installation Procedures On The Built-In Hdd

    This section concisely describes the procedures for installing Windows on the built-in HDD. Confirm the MMB configuration and successful login to the MMB before starting the installation.For details on configuring the SAN storage unit and FC card (Fibre Channel card), see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN).
  • Page 111: Table 4.6 Operating System Installation By Svim

    Operations 1. Make the setting for booting the partition from remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 112: Figure 4.7 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 113: Figure 4.8 [Mode] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software 8. Replace the media with the operating system installation media according to the SVIM instructions. 9. Perform the following operation by using the MMB Web-UI. Remarks These steps are not required in Windows Server 2012.
  • Page 114: Figure 4.9 [Install Windows] Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software FIGURE 4.9 [Install Windows] window 2. When the [Install Windows] window appears after a system reboot following termination of the [Installing updates] window with the [Install Windows] window displayed as is in 1. above.
  • Page 115: Configuring Bundled Software After The Completion Of Installation

    Note The downloaded binary file has a description about the PRIMERGY, but the driver and utility can be used for the PRIMEQUEST 1000 series. 2. Execute the downloaded file by double-clicking it. The prompt screen for the cmd.exe (a window with a black background) is displayed for a while, and then the file is extracted.
  • Page 116: Table 4.7 If The Folder Contains Two Files

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software - If the folder contains the following two files, select a file according to the Windows type. TABLE 4.7 If the folder contains two files OS type...
  • Page 117 12. Configure the dump area. Confirm that the hard disk has enough free space before collecting a memory dump. For details, see 11.4.4 Setting up the dump environment (Windows) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 13. Configure the NTP client.
  • Page 118: Connecting The San And Built-In Hdd After The Installation

    4.5.5 Connecting the SAN and built-in HDD after the installation For details on connecting the SAN and built-in HDD after the installation, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN). 1. Change and check the setting of detailed FC card information. For details, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN).
  • Page 119: Vmware 4.X Installation Procedures On The San Storage Unit

    SAS controller (GSPB), SAS disk unit controller and SAS array disk unit controller. For details on I/O space assignment, see 3.4.5 Setting various modes and 5.5.1 [Configure I/O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.6.2 Preparing for Installation To prepare for installation, also see the VMware information.
  • Page 120: Installing Vmware 4.X

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software 2. Change FC cabling to single path (connecting only one FC cable). 4.6.3 Installing VMware 4.x Install VMware 4.x by following the instructions in the VMware vSphere Software Handbook.
  • Page 121: Configuring A Software Watchdog

    - Enter a value between 1 and 100 minutes for [Timeout]. 6. Enter your user name and password, and press the [Enter] key. 4.6.7 Completing VMware 4.x installation After completing the settings, reboot the partition of the PRIMEQUEST 1000 series server. C122-E107-09EN...
  • Page 122: Vmware 4.X Installation Procedures On The Built-In Hdd

    MegaRAID (R) SAS Software contained on the SVS DVD. 5. Change the boot order to give the highest priority in startup to DVD boot. For details, see 1.3.1 [Power Control] window in the PRIMEQUEST 1000 Series Tool Reference (C122- E110EN).
  • Page 123: Installing Vmware 4.X

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software 4.7.3 Installing VMware 4.x Install VMware 4.x by following the instructions in the VMware vSphere Software Handbook. For details on this handbook, contract your sales representative.
  • Page 124: Configuring A Software Watchdog

    - Enter a value between 1 and 100 minutes for [Timeout]. 6. Enter your user name and password, and press the [Enter] key. 4.7.7 Completing VMware installation After completing the settings, reboot the partition of the PRIMEQUEST 1000 series server. C122-E107-09EN...
  • Page 125: Vmware 5.X Installation Procedures On The San Storage Unit

    SAS controller (GSPB), SAS disk unit controller and SAS array disk unit controller. For details on I/O space assignment, see 3.4.5 Setting various modes in this manual and 5.5.1 [Configure I/ O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.8.2 Preparing for Installation To prepare for installation, also see the VMware information.
  • Page 126: Installing Vmware 5.X

    Operations 1. Make the setting for booting the partition from remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 127: Figure 4.11 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 128: Configuring A Software Watchdog

    - Enter a value between 1 and 100 minutes for [Timeout]. 6. Enter your user name and password, and press the [Enter] key. 4.8.5 Completing VMware 5.x installation After completing the settings, reboot the partition of the PRIMEQUEST 1000 series server. 4.8.6 Installing bundled software For bundled software installation, see E.7 Installing VMware 5.x Bundled...
  • Page 129: Vmware 5.X Installation Procedures On The Built-In Hdd

    MegaRAID (R) SAS Software contained on the SVS DVD. 5. Change the boot order to give the highest priority in startup to DVD boot. For details, see 1.3.1 [Power Control] window in the PRIMEQUEST 1000 Series Tool Reference (C122- E110EN).
  • Page 130: Installing Vmware 5.X

    Operations 1. Make the setting for booting the partition from remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 131: Figure 4.12 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 132: Configuring A Software Watchdog

    - Enter a value between 1 and 100 minutes for [Timeout]. 6. Enter your user name and password, and press the [Enter] key. 4.9.5 Completing VMware 5.x installation After completing the settings, reboot the partition of the PRIMEQUEST 1000 series server. 4.9.6 Installing bundled software For bundled software installation, see E.7 Installing VMware 5.x Bundled...
  • Page 133: Suse Linux Enterprise Server 11 Service Pack 2 Installation Procedures On The San Storage Unit

    SAS controller (GSPB), SAS disk unit controller and SAS array disk unit controller. For details on I/O space assignment, see 3.4.5 Setting various modes in this manual and 5.5.1 [Configure I/ O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.10.2 Preparing for Installation Prepare a SLES11 SP2 installation DVD.
  • Page 134: Installing The Operating System

    Operations 1. Make the setting for booting the partition from remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 135: Figure 4.13 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 136: Configuring Bundled Software After The Completion Of Installation

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software Remark The IP address of the LAN cannot be set through the operating system setup. Set the IP address after the installation of the operating system.
  • Page 137: Connecting The San And Built-In Hdd After The Installation

    Connecting the SAN and built-in HDD after the installation For details on connecting the SAN and built-in HDD after the installation, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN). Also, for details on driver parameters, see the readme file that comes with the driver.
  • Page 138: Suse Linux Enterprise Server 11 Service Pack 2 Installation Procedures On The Built-In Hdd

    SAS array disk unit controller. For details on I/O space assignment, see 3.4.5 Setting various modes in this manual and 5.5.1 [Configure I/ O Space Assignment] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). 4.11.2 Preparing for Installation Prepare the SLES11 SP2 installation DVD.
  • Page 139 Operations 1. Make the setting for booting the partitionfrom remote storage. For details on the setting, see 1.6.3 Remote operation (BMC) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 2. Insert ServerView Suite DVD1 into the DVD drive. Then, power on the partition.
  • Page 140: Figure 4.14 Example Of Display Of The [Change Boot Order] Menu

    - UEFI: Embedded DVD/CD: Specify this item when using the built-in DVD drive for installation in UEFI mode. - UEFI Shell: Specify this menu when starting UEFI Shell. The PRIMEQUEST 1000 series does not use UEFI Shell. - Legacy Boot: Specify this item for BIOS mode.
  • Page 141: Configuring Bundled Software After The Completion Of Installation

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 4 Installing the Operating System and Bundled Software Remark The IP address of the LAN cannot be set through the operating system setup. Set the IP address after the installation of the operating system.
  • Page 142: Connecting The San And Built-In Hdd After The Installation

    Connecting the SAN and built-in HDD after the installation For connecting the SAN and built-in HDD after the installation, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN). Also, for details on driver parameters, see the readme file that comes with the driver.
  • Page 143: Chapter 5 Work After Operating System Installation (Primequest 1800E2)

    CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) This chapter describes how to make settings after operating system installation on the PRIMEQUEST 1800E2. 5.1 Types of Work ............116 5.2 Configuring SVS (SVagent/SVmco) ......117 5.3 Setting Up the Dump Environment (Windows) ..
  • Page 144: Types Of Work

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) Types of Work TABLE 5.1 Types of work lists the types and details of the work performed after operating system installation. TABLE 5.1 Types of work...
  • Page 145: Configuring Svs (Svagent/Svmco)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) Configuring SVS (SVagent/SVmco) After installing the operating system, you need to configure SVS (SVagent/SVmco) for operation. For details on SVagent/SVmco settings, see the SVmco manual. - SVagent:...
  • Page 146: Setting Up The Dump Environment (Windows)

    For details on how to set up the dump environment, see 11.4.4 Setting up the dump environment (Windows) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 5.3.1 Memory dump files and paging files A memory dump file stores debug information on any STOP error (fatal system error) that has occurred in the system.
  • Page 147: Setting Up The Dump Environment (Linux)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) Setting Up the Dump Environment (Linux) In RHEL, you can prepare an environment to enable secure acquisition of dumps by using the standard operating system function kdump.
  • Page 148: Configuring The Ntp Client

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) Configuring the NTP Client For details on how to configure the NTP client, see 7.2 Configuring NTP. C122-E107-09EN...
  • Page 149: Saving Management And Configuration Information

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) Saving Management and Configuration Information This section describes how to save the following information. Be sure to save UEFI configuration information. 5.6.1 Saving MMB configuration information 5.6.2 Saving BIOS configuration information...
  • Page 150: Saving Bios Configuration Information

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) The backup file of the MMB configuration information has the following default name: MMB_backup date_MMB version.dat 5.6.2 Saving BIOS configuration information This section describes how to back up BIOS configuration information to a remote PC.
  • Page 151: Configuring Service Life Monitoring By Ras Support Service

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) Configuring Service Life Monitoring by RAS Support Service For the use of RAID cards and UPSs, configure the BBU (Battery Backup Unit) service life monitoring by RAS Support Service.
  • Page 152: Battery Unit Service Life Monitoring For A Ups

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) - After moving a monitored RAID card to another partition through a partition configuration change, you need to correct the RAS Support Service settings. First, in the Mounting Dates list, clear the RAID card mounting date on the original source partition.
  • Page 153 PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) TABLE 5.3 Message for advance notification of replacement and replacement notification message (UPS) Start time for sending messages for advance Time for sending replacement notification of replacement...
  • Page 154 PRIMEQUEST 1000 Series Installation Manual CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2) C122-E107-09EN...
  • Page 155: Chapter 6 Work After Operating System Installation (Primequest 1800E)

    CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) This chapter describes how to make PSA and other settings after operating system installation on the PRIMEQUEST 1800E. 6.1 Types of Work ............128 6.2 Configuring PSA (Linux: Red Hat Enterprise Linux) ..
  • Page 156: Types Of Work

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Types of Work TABLE 6.1 Types of work lists the types and details of the work performed after operating system installation. TABLE 6.1 Types of work...
  • Page 157: Configuring Psa (Linux: Red Hat Enterprise Linux)

    *2 Manual setting: Values are not automatically set during PSA installation. Make settings as described in the section referred to in the table. *3 To operate the PRIMEQUEST 1000 series server, you need to first install PSA. Otherwise, the following restrictions apply.
  • Page 158: Configuring The Psa-To-Mmb Communication Lan

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) - Operations management software cannot collect information on the partition side. - Even under an REMCS agreement, no software errors are reported. - Hot maintenance of hard disks is disabled. The partition must be stopped for maintenance.
  • Page 159 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) The PSA-to-MMB communication LAN is usually set with the following values during PSA installation. <IP address> 172.30.0.<partition ID + 2>/24 Example: Partition ID of 2 172.30.0.4/24 <Communication settings>...
  • Page 160 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) eth0, eth1, and lo shown on the left side are the interface names. /sbin/ifconfig -a eth0 Link encap:Ethernet HWaddr 00:D0:B7:53:89:C3 inet addr:10.24.17.149 Bcast:10.24.17.255 Mask:255.255.255.0 inet6 addr:...
  • Page 161 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) bus-info: 0000:00:19.0 (Corresponds to NIC of PSA-to-MMB communication LAN) Configuring the NIC of the PSA-to-MMB communication LAN Configure the NIC of the PSA-to-MMB communication LAN by using the following procedure.
  • Page 162: Confirming Management Lan Settings

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 6.2.2 Confirming management LAN settings Make network settings for the management LAN. If necessary, also configure any duplication with bonding or PRIMECLUSTER GLS, for example. After completing the above network settings for the management LAN, perform the operations described in 6.2.4...
  • Page 163: Checking The Firewall Function (Opening Ports)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 6.2.4 Checking the firewall function (opening ports) Open any partition port that is required for operating PSA but is not open because of firewall settings. Configure the management LAN interfaces and PSA-to-MMB communication LAN interfaces.
  • Page 164 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) The following is a sample configuration file. /opt/FJSVpsa/sh/sample_conf_setmlanfw.txt Remarks A PSA update will overwrite the above sample file. Save a copy of the configuration file to retain the original values.
  • Page 165 After changing the IP address of the management LAN interface, delete the settings once, and set their values again. For details on how to delete the settings, see (7) Configuration deletion procedure in 4.11 Firewall Setting Command for the Management LAN Interface (setmlanfw.sh) in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN).
  • Page 166 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Chain OUTPUT (policy ACCEPT) target prot source destination Chain MMLAN (2 references) target prot source destination ACCEPT 192.168.0.0/24 192.168.0.1 udp dpts:7000:7100 ACCEPT 192.168.0.1 192.168.0.0/24 udp spts:7000:7100 ACCEPT 192.168.0.0/24...
  • Page 167: Table 6.5 Ports To Open For The Psa-To-Mmb Communication Lan Interfaces

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) MMLAN 0.0.0.0/0 0.0.0.0/0 Chain MMLAN (2 references) target prot source destination ACCEPT 192.168.0.0/24 192.168.0.1 udp dpts:7000:7100 ACCEPT 192.168.0.1 192.168.0.0/24 udp spts:7000:7100 ACCEPT 192.168.0.0/24 192.168.0.1 udp dpt:162 ACCEPT 192.168.0.1...
  • Page 168: Setting The Destinations Of Traps From A Partition

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Port Port number Description Remarks Example of a case where port 5000 need not be set: iptables -A OUTPUT -m state --state NEW,ESTABLISH -j ACCEPT iptables -A INPUT -m state --state...
  • Page 169 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Example of input [PSATRAP] PSATRAP_SET=1 2. Set trap destinations in the snmpd.conf file. For details, see Editing snmpd.conf. 3. Restart PSA to apply the settings. Syntax...
  • Page 170: Table 6.6 Seclevel Settings

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) The following example shows how to send traps with "public" as the community name. The traps are sent to the manager of port 162 with IP address 192.168.0.162.
  • Page 171 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) -A authPassword: This is the authentication password (at least eight characters). This setting must match that on the manager side. The option takes effect only if the security level in the -l option includes authentication. Otherwise, you can omit the option.
  • Page 172: Setting The Destinations Of Traps And E-Mail Via The Mmb

    Setting the management LAN IP address Set the partition management LAN IP address in PSA. For details on the management LAN, see 1.3 Management LAN in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). Note Here, set the IP address on the partition instead of the IP address on the MMB.
  • Page 173: Configuring Snmp To Use Duplicate Disks

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) [NETWORK] ManagementIP=192.168.0.1 Restart PSA to reflect the new NIC setting for the management LAN. Syntax /sbin/service y30FJSVpsa stop /sbin/service y10FJSVpsa start /sbin/service y30FJSVpsa start For details on how to specify any duplication of the management LAN with PRIMECLUSTER GLS, see the applicable PRIMECLUSTER manuals.
  • Page 174 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 4566 ? 0:01 /opt/FJSVpsa/bin/mmbs -p / 4567 ? 0:02 /opt/FJSVpsa/bin/fs -p / 4568 ? 0:00 /opt/FJSVpsa/bin/ciipmi -p / 4569 ? 7:40 /opt/FJSVpsa/bin/cilog -p / 4570 ?
  • Page 175: Installing A Psa Update

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) /var/net-snmp/snmpd.conf oldEngineID 0x19760523 6. Execute the service command to start snmpd. Syntax /sbin/service snmpd start 7. Move to the /opt/FJSVpsa/sh/ directory to generate another SNMPv3 password for internal PSA communication.
  • Page 176: Uninstalling Psa

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) /sbin/service y30FJSVpsa start 6.2.10 Uninstalling PSA This section describes how to uninstall PSA in Red Hat Enterprise Linux. Execute the following commands in the order shown to first stop PSA services and then uninstall the PSA package.
  • Page 177: Configuring Psa (Windows Server 2003)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Configuring PSA (Windows Server 2003) This section describes confirmation of the required settings for PSA operation after operating system installation, and corresponding features about the settings.
  • Page 178: Table 6.8 Settings Automatically Added/Changed During Psa Installation

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) - SVIM installs PSA as it installs the operating system. For details on SVIM, see the ServerView Installation Manager. - For details on how to manually install PSA, see...
  • Page 179: Configuring The Psa-To-Mmb Communication Lan

    CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) - Execute the SNMP security setting command (setsnmpsec) in the following situations. For details on the command, see 4.8 SNMP Security Setting Command (setsnmpsec) in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN).
  • Page 180 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) [PSA installation folder]\opt\FJSVpsa\sh\setpsalan.bat Note If the operating system has not been restarted after PSA installation, the PSA-to-MMB communication LAN setting command in step 1 will fail.
  • Page 181: Confirming Management Lan Settings

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 2. Select [PSANIF] from the displayed list. Then, select [Properties] from the right-click menu. Notes - If there is no connection named [PSANIF], PSA has probably not been installed. Always change the settings after PSA installation.
  • Page 182 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) - Make settings only as needed. Operations management software needs these settings to manage events by partition. - Even if this setting is skipped, traps are sent via the MMB.
  • Page 183: Setting The Destinations Of Traps And E-Mail Via The Mmb

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 12. Click [Action] - [Restart] to restart SNMP Service. Restarting PSA 1. Click [Start menu] - [Administrative Tools] - [Services]. 2. Select [PRIMEQUEST Server Agent] in the right side of the window.
  • Page 184: Figure 6.1 [Add A Port] Dialog Box (Psa)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Operations 1. Select [Control Panel] - [Windows Firewall]. >> The [Windows Firewall] window appears. 2. Click the [Exceptions] tab. Then, click the [Add Port] button. >> The [Add a Port] dialog box appears.
  • Page 185: Setting The Watchdog Timer For Monitoring After A Stop Error (Fatal System Error)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.2 [Add a Port] dialog box (SNMP) 5. Enter the port number used by SNMP. Then, click the [OK] button. 6. Click the [OK] button in the [Windows Firewall] window.
  • Page 186: Setting The Management Lan Ip Address

    Setting the management LAN IP address Set the partition management LAN IP address in PSA. For details on the management LAN, see 1.3 Management LAN in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). Note Here, set the IP address on the partition instead of the IP address on the MMB.
  • Page 187: Figure 6.3 Preparing To Install Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 2. Start the saved fix program. The following window appears for installation preparations. FIGURE 6.3 Preparing to Install window 3. The following window appears when installation preparations are completed. Click the [Next] button to proceed.
  • Page 188: Figure 6.4 Update Installation Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.4 Update installation window 4. Click the [Finish] button. C122-E107-09EN...
  • Page 189: Uninstalling Psa

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.5 Update installation complete window 5. You may need to restart your computer. If so, a confirmation dialog box appears. The dialog box asks whether you want to restart the computer immediately.
  • Page 190: Figure 6.7 Uninstall Complete Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 3. Click the [OK] button. >> Uninstallation begins. Immediately after uninstallation is completed, the maintenance complete window appears. 4. Click the [Finish] button. FIGURE 6.7 Uninstall Complete window 5.
  • Page 191: Configuring Psa (Windows Server 2008)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Configuring PSA (Windows Server 2008) This section describes confirmation of the required settings for PSA operation after operating system installation, and corresponding features about the settings.
  • Page 192: Table 6.10 Settings Automatically Added/Changed During Psa Installation

    - The installer installs some components for REMCS function on the operating system side during PSA installation. Only Fujitsu certified service engineers make settings for REMCS. The following table lists settings for PSA operation. The installer automatically adds or updates these settings during PSA installation.
  • Page 193: Configuring The Psa-To-Mmb Communication Lan

    Remarks - Execute the SNMP security setting command (setsnmpsec) in the following situations. For details on the command, see 4.8 SNMP Security Setting Command (setsnmpsec) in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). - Having installed PSA, you will be changing the SNMP Service security setting from [Accept SNMP packets from any host] to [Accept SNMP packets from these hosts].
  • Page 194: Installing The Pshed Plugin Driver

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 6.4.3 Installing the PSHED Plugin driver The PSHED Plugin driver expands the WHEA (Windows Hardware Error Architecture) functions. This driver is not automatically installed. Manually install the driver with the batch file (plugin_install.bat) stored in the following folder.
  • Page 195: Setting The Destinations Of Traps From A Partition

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 3. Confirm that [PRIMEQUEST PSHED Plugin Driver] appears under [System Devices] in the Device Manager. If the Device Manager does not display the driver, repeat the procedure from step 1.
  • Page 196: Setting The Destinations Of Traps And E-Mail Via The Mmb

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 7. Click [Add] in [Trap Send Destination]. Enter the host name or IP address of the server receiving the trap (i.e., the trap destination). Then, click [Add].
  • Page 197: Figure 6.8 Windows Firewall Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) - SNMP Service uses UDP port 161 (to receive data from the MMB). - fjpsawg.exe uses TCP port 24450 (to receive data from the MMB). - fjpsammbs.exe uses a port to send data to the MMB (TCP port 5000 on the MMB side).
  • Page 198: Figure 6.9 [General] Tab In [Snmp Service (Udp In) Properties]

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.9 [General] tab in [SNMP Service (UDP In) Properties] 5. Click the [Scope] tab. Select [Any IP address] for [Local IP Address]. Select [These IP Addresses] in [Remote IP Address]. Then, click the [Add] button.
  • Page 199: Figure 6.10 [Scope] Tab In [Snmp Service (Udp In) Properties]

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.10 [Scope] tab in [SNMP Service (UDP In) Properties] 6. The [IP Address] dialog box appears. Click [Predefined set of computers]. Select [Local subnet] from the list. Then, click the [OK] button.
  • Page 200: Figure 6.11 [Ip Address] Dialog Box

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.11 [IP Address] dialog box 7. Click the [OK] button to close the [SNMP Service (UDP In) Properties] dialog box. 8. Click [New Rule] in the right pane of the [Windows Firewall with Advanced Security] window. The [New Inbound Rule Wizard] window appears with [Rule Type] displayed at the top left.
  • Page 201: Figure 6.12 New Inbound Rule Wizard - Rule Type

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.12 New Inbound Rule Wizard - Rule Type 9. The wizard displays the [Program] window, as indicated at the upper left. Select [This program path]. Then, click the [Browse] button.
  • Page 202: Figure 6.13 New Inbound Rule Wizard - Program

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.13 New Inbound Rule Wizard - Program 10. The wizard displays the [Protocol and Ports] window, as indicated at the upper left. Select or enter values for the following items.
  • Page 203: Figure 6.14 New Inbound Rule Wizard - Protocol And Ports

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.14 New Inbound Rule Wizard - Protocol and Ports 11. The wizard displays the [Scope] window, as indicated at the upper left. Select or enter values for the following items.
  • Page 204: Figure 6.15 New Inbound Rule Wizard - Scope

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.15 New Inbound Rule Wizard - Scope 12. The wizard displays the [Action] window, as indicated at the upper left. Select [Allow the connection]. Then, click the [Next] button.
  • Page 205: Figure 6.16 New Inbound Rule Wizard - Action

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.16 New Inbound Rule Wizard - Action 13. The wizard displays the [Profile] window, as indicated at the upper left. Check all the [Domain], [Private], and [Public] check boxes.
  • Page 206: Figure 6.17 New Inbound Rule Wizard - Profile

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.17 New Inbound Rule Wizard - Profile 14. The wizard displays the [Name] window, as indicated at the upper left. Enter "PSAWG" in [Name]. Then, click the [Finish] button.
  • Page 207: Figure 6.18 New Inbound Rule Wizard - Name

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.18 New Inbound Rule Wizard - Name 15. Click [Outbound Rules] in the left pane of the [Windows Firewall with Advanced Security] window. The [Outbound Rules] list appears in the center pane.
  • Page 208: Figure 6.19 New Outbound Rule Wizard - Protocol And Ports

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) TABLE 6.13 [Protocol and Ports] setting items Window item Selected or entered value Protocol type Local port All Ports Remote port Select [Specific Ports]. Then, enter 5000 in the text box below it.
  • Page 209 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Window item Selected or entered value Enter the IP address of the PSA-to-MMB communication LAN on the MMB side. 20. The wizard displays the [Action] window, as indicated at the upper left. Select [Allow the connection]. Then, click the [Next] button.
  • Page 210: Figure 6.20 New Outbound Rule Wizard - Protocol And Ports

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.20 New Outbound Rule Wizard - Protocol and Ports 26. The wizard displays the [Scope] window, as indicated at the upper left. Select or enter values for the following items.
  • Page 211: Setting The Watchdog Timer For Monitoring After A Stop Error (Fatal System Error)

    Setting the management LAN IP address Set the partition management LAN IP address in PSA. For details on the management LAN, see 1.3 Management LAN in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). Note Here, set the IP address on the partition instead of the IP address on the MMB.
  • Page 212: Installing A Psa Update

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) [NETWORK] ManagementIP=192.168.0.1 Restart PSA to reflect the new NIC settings for the management LAN. Restarting PSA 1. Click [Start] - [Administrative Tools] - [Services]. 2. Select [PRIMEQUEST Server Agent] in the right side of the window.
  • Page 213: Figure 6.21 Preparing To Install Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.21 Preparing to Install window 3. The following window appears when installation preparations are completed. Click the [Next] button to proceed. >> The program update begins.
  • Page 214: Figure 6.23 Update Installation Complete Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) After completing PSA installation including an update to the PSHED Plugin driver, be sure to confirm that the operating system can be restarted before you restart the operating system.
  • Page 215: Uninstalling Psa

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.24 Program removal window 6.4.10 Uninstalling PSA This section describes the PSA uninstallation procedure. Remarks Uninstalling PSA deletes all the files in the PSA installation folder. Save the necessary files before uninstallation.
  • Page 216: Figure 6.25 [Program And Features] Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.25 [Program and Features] window 2. Select [PRIMEQUEST Server Agent] from the list of currently installed programs. Then, click [Remove]. The Preparing to Install window appears. Then, a deletion confirmation message appears.
  • Page 217: Figure 6.26 Preparing To Install Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.26 Preparing to Install window 3. Click the [Yes] button. >> Uninstallation begins. FIGURE 6.27 Confirmation message dialog box Immediately after uninstallation is completed, the Uninstall Complete window appears.
  • Page 218: Figure 6.28 Uninstall Complete Window

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.28 Uninstall Complete window 4. Click the [Finish] button. 5. To delete the PSHED Plugin driver, you need to restart the operating system. Be sure to confirm that the operating system can be restarted, before restarting it.
  • Page 219: Setting Up The Dump Environment (Windows)

    For details on how to set up the dump environment, see 11.4.4 Setting up the dump environment (Windows) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). 6.5.1 Memory dump files and paging files A memory dump file stores debug information on any STOP error (fatal system error) that has occurred in the system.
  • Page 220: Setting Up The Dump Environment (Linux)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Setting Up the Dump Environment (Linux) In RHEL, you can prepare an environment to enable secure acquisition of dumps by using the standard operating system function kdump.
  • Page 221: Configuring The Ntp Client

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) Configuring the NTP Client For details on how to configure the NTP client, see 7.2 Configuring NTP. C122-E107-09EN...
  • Page 222: Saving Management And Configuration Information

    - Deleting an exported file from the partition management area Operations 1. Select [Partition] - [Partition#x] - [PSA] - [Export List]. >> The [Export List] window appears. For details on the [Export List] window, see 3.11 [Export List] Window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 223: Figure 6.29 [Export List] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.29 [Export List] window (example) 2. Click the button appropriate to your operation. - Saving a snapshot to a file in CSV format: Click the [Export] button.
  • Page 224: Saving Mmb Configuration Information

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) You can use the following characters in a keyword: Single-byte alphanumeric characters Single-byte space Single-byte symbols (except < > % & " , \ ) FIGURE 6.30 [Export] window (example) 2.
  • Page 225: Saving Bios Configuration Information

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.31 [Backup/Restore MMB Configuration] window (example) 2. Click the [Backup] button. >> The save destination dialog box of the browser appears. 3. Select the save destination path. Then, click the [OK] button.
  • Page 226: Figure 6.32 [Backup Bios Configuration] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) FIGURE 6.32 [Backup BIOS Configuration] window (example) 2. Select the radio button of the partition to which to back up the configuration information. Then, click the [Backup] button.
  • Page 227: Configuring Service Life Monitoring By Ras Support Service

    In the Mounting Dates list, enter the mounting dates of the RAID cards for which to set service life monitoring. Notes Note the following points about BBU service life monitoring for a RAID card in the PRIMEQUEST 1000 series server.
  • Page 228: Figure 6.33 Ras Support Service Screens (No Bbu)

    FIGURE 6.34 RAS Support Service screens (move to another partition) - The PRIMEQUEST 1000 series server can have multiple partition configurations. For example, suppose a partition requires many CPUs during the day and a lot of I/O at night, the partition configuration must change between day and night.
  • Page 229: Battery Unit Service Life Monitoring For A Ups

    Since you can enter a value in the Mounting Dates list, enter the battery unit mounting date in the list. Notes Note the following points about battery unit service life monitoring for a UPS in the PRIMEQUEST 1000 series server.
  • Page 230: Recovery Procedure After The Execution Of The Simple Setup Tool (Editconf.sh)

    ## Setup for FJSVpsa Please do not remove the following lines ## #sv#com2sec psalocal localhost psaprivate <- #sv#group PsaRWGroup v1 psalocal <- #sv#view fujitsu included .1.3.6.1.4.1.211.1.31.1 ff.c0 <- #sv#access PsaRWGroup "" any noauth exact fujitsu fujitsu none <- rouser fjsvpsa master agentx agentxTimeout 360 agentxRetries 0 sysobjectid .1.3.6.1.4.1.211.1.31.1.2.100.2.0...
  • Page 231 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) 3. To reflect the setting, restart PSA. /sbin/service y30FJSVpsa stop /sbin/service y30FJSVpsa start C122-E107-09EN...
  • Page 232 PRIMEQUEST 1000 Series Installation Manual CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E) C122-E107-09EN...
  • Page 233: Chapter 7 Work After Installation

    CHAPTER 7 Work after Installation This chapter describes the work performed after PRIMEQUEST 1000 series installation. This work includes configuring NTP and security. 7.1 Duplicate Network Adapter Configuration ....206 7.2 Configuring NTP ............207 7.3 Configuring a DNS Server ........
  • Page 234: Duplicate Network Adapter Configuration

    Disabled on the standby side FIGURE 7.1 External network configuration Note There are some precautions on teaming with Intel PROSet(R). For details on the precautions, see APPENDIX G. 8 NIC (Network Interface Card) in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). C122-E107-09EN...
  • Page 235: Configuring Ntp

    How NTP operates in the PRIMEQUEST 1000 series This section describes how NTP is used to correct the time of each partition in the PRIMEQUEST 1000 series. The time is set at the following two types of units in the PRIMEQUEST 1000 series server:...
  • Page 236: Setting An Ntp Server

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation FIGURE 7.2 Operation with external NTP servers (three NTP servers) Only a single NTP server can be specified for a client. In this case, if the NTP client is no longer able to communicate with the specified server, NTP server communication is lost because no other synchronized server is available.
  • Page 237: Figure 7.3 [Date/Time] Window (Example)

    Operations 1. Click [Network Configuration] - [Date/Time]. The [Date/Time] window appears. For details on the [Date/Time] window, see 1.5.1 [Date/Time] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 7.3 [Date/Time] window (example) 2. Click [Enable] for [NTP]. 3. Enter the IP address of another NTP server.
  • Page 238 PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation 5. After several minutes elapse, click the [Refresh] button. Then, confirm that the window displays the correct time. C122-E107-09EN...
  • Page 239: Configuring A Dns Server

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation Configuring a DNS Server For details on how to configure a DNS server, see 3.3.8 Configuring a DNS server. C122-E107-09EN...
  • Page 240: Configuring Smtp

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation Configuring SMTP For details on how to configure SMTP, see 3.3.9 Configuring Alarm E-Mail. C122-E107-09EN...
  • Page 241: Configuring Security

    Selecting the filter to edit Operations 1. Click [Network Configuration] - [Access Control]. The [Access Control] window appears. For details on the [Access Control] window, see 1.5.10 [Access Control] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 242: Figure 7.4 [Access Control] Window (Example)

    Depending on whether you are adding or editing the filter, the [Add Filter] window or [Edit Filter] window appears. For details on the [Add Filter] and [Edit Filter] windows, see [Add Filter]/[Edit Filter] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 243: Figure 7.5 [Add Filter] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation FIGURE 7.5 [Add Filter] window (example) 2. Enter values in the required fields. You can set up to 64 filters. Remarks Specify the IP address while taking account of the proxy setting for the Web browser on the PC or workstation.
  • Page 244: Configuring Snmp

    1. Click [Network Configuration] - [Network Protocols]. The [Network Protocols] window appears. For details on the [Network Protocols] window, see 1.5.4 [Network Protocols] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 7.6 [Network Protocols] window (example) 2. Enter values for each item in [SNMP].
  • Page 245: Figure 7.7 [Snmp Community] Window (Example)

    CHAPTER 7 Work after Installation The [SNMP Community] window appears. For details on the [SNMP Community] window, see [SNMP Community] window in 1.5.6 [SNMP Configuration] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 7.7 [SNMP Community] window (example) 2.
  • Page 246: Figure 7.8 [Snmp Trap] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation FIGURE 7.8 [SNMP Trap] window (example) 2. Enter destinations. You can set up to 16 trap destinations. Set the community or user name, IP address of the trap destination, SNMP version, and authentication level.
  • Page 247: Configuring Ssh

    1. Click [Network Configuration] - [SNMP Configuration] - [SNMP v3 Configuration]. The [SNMP v3 Configuration] window appears. For details on the [SNMP v3 Configuration] window, see [SNMP v3 Configuration] window in 1.5.6 [SNMP Configuration] menu in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN).
  • Page 248: Configuring Https

    Specify a "verified certificate" as the valid SSL certificate. Alternatively, specify a "self-signed certificate" created in the MMB window. A Fujitsu certified service engineer may have already configured HTTPS. If no change is needed, proceed to the next setting item.
  • Page 249: Figure 7.11 [Network Protocols] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation FIGURE 7.11 [Network Protocols] window (example) 2. Specify each HTTPS-related item in [HTTP]. 3. Click the [Apply] button. C122-E107-09EN...
  • Page 250: Scheduled Operations

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 7 Work after Installation Scheduled Operations For details on scheduled operations, see 9.3 Scheduled Operations in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). C122-E107-09EN...
  • Page 251: Chapter 8 Powering On And Off A Partition

    CHAPTER 8 Powering On and Off a Partition This chapter describes partition power control. 8.1 Powering On and Off a Partition ......224...
  • Page 252: Powering On And Off A Partition

    2. Click [Partition] - [Power Control]. The [Power Control] window appears. For details on the [Power Control] window, see 1.3.1 [Power Control] window in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). FIGURE 8.1 [Power Control] window (example) 3. Select [Power On] in [Power Control] for the partition that you are going to power on. Then, click the [Apply] button.
  • Page 253: Powering Off A Partition

    If the following problems occur, check for details on the problem in 11.2.11 Problems with partition operations in the PRIMEQUEST 1000 Series Administration Manual (C122-E108EN). - The MMB Web-UI displays [Error] for [Status] (information area) because either of the following was...
  • Page 254: Figure 8.2 [Power Control] Window (Example)

    PRIMEQUEST 1000 Series Installation Manual CHAPTER 8 Powering On and Off a Partition FIGURE 8.2 [Power Control] window (example) 3. Select [Power Off] in [Power Control] for the partition that you are going to power off. Then, click the [Apply] button.
  • Page 255: Appendix A Lists Of Settings (Links)

    APPENDIX A Lists of Settings (Links) See Appendix A Lists of Settings in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). A.1 MMB Settings ............228 A.2 PSA Settings ............229 A.3 UEFI Settings ............230 A.4 BMC Settings ............231...
  • Page 256: Mmb Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings (Links) MMB Settings See A.1 MMB Web-UI Settings in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 257: Psa Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings (Links) PSA Settings See A.2 PSA Settings in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 258: Uefi Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings (Links) UEFI Settings See A.3 UEFI Settings in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 259: Bmc Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings (Links) BMC Settings See A.4 BMC Settings in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). C122-E107-09EN...
  • Page 260 PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings (Links) C122-E107-09EN...
  • Page 261: Appendix B Manual Psa Installation And Uninstallation

    APPENDIX B Manual PSA Installation and Uninstallation This appendix describes how to manually install and uninstall PSA for a specific operating system. If you use SVIM to install the operating system, you need not manually install PSA. Remarks PSA is provided only with the PRIMEQUEST 1800E. B.1 Manually Installing PSA (Linux: Red Hat Enterprise Linux) ................
  • Page 262: Manually Installing Psa (Linux: Red Hat Enterprise Linux)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation Manually Installing PSA (Linux: Red Hat Enterprise Linux) This section describes how to manually install PSA in Linux (Red Hat Enterprise Linux). Remarks Be sure to install PSA for PRIMEQUEST 1800E. Otherwise, the following restrictions apply.
  • Page 263: Table B.1 Packages Required For Psa Operation (Rhel5)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation TABLE B.1 Packages required for PSA operation (RHEL5) Package CPU architecture Linux package gdb-x.x-x.x.i386.rpm gdb-x.x-x.x.x86_64.rpm lm_sensors-x.x.x-x.x.i386.rpm lm_sensors-x.x.x-x.x.i386.rpm net-snmp-x.x.x.x-x.x.i386.rpm lm_sensors-x.x.x-x.x.x86_64.rpm net-snmp-utils-x.x.x.x- net-snmp-x.x.x.x-x.x.x86_64.rpm x.x.i386.rpm net-snmp-libs-x.x.x.x-x.x.i386.rpm rcs-x.x-x.x.i386.rpm net-snmp-libs-x.x.x.x-x.x.x86_64.rpm net-snmp-utils-x.x.x.x-x.x.x86_64.rpm popt-x.x.x.x-x.x.i386.rpm rcs-x.x-x.x.x86_64.rpm rpm-libs-x.x.x.x-x.x.i386.rpm...
  • Page 264: Table B.3 Packages Required For Sirms Operation (Rhel6)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation TABLE B.3 Packages required for SIRMS operation (RHEL6) Package CPU architecture Linux package Not required libstdc++-4.4.4-13.el6.i686 or later Note The name of the FJSVfefpcl-related package depends on the operating system version.
  • Page 265: Installing Psa

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation - To use a firewall tool other than iptables: Stop the iptables service. B.1.3 Installing PSA Execute the following command to install the PSA package. The following explanation is based on the assumption that the PSA package (FJSVpsa-$VER-$REL.tar.gz) has...
  • Page 266: Restarting The Partition

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation Target Action Remarks SELinux setting The policy module is added for RHEL6 or later only. setting B.1.5 Restarting the partition After installing PSA, restart the partition with a reboot.
  • Page 267 PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation If PSA version 2.8.0 or earlier is installed when the iptables service has stopped, the existing settings are cleared. Deal with this problem in the following way. - To use the iptables service: After making the settings to open the ports necessary for the system, open the necessary ports.
  • Page 268 PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation ACCEPT 0.0.0.0/0 0.0.0.0/0 tcp dpt:5000 1. Confirm that the PSA-MMB_LAN chain has been created. # /sbin/iptables -L # iptables -L Execution result Chain INPUT (policy ACCEPT) target prot...
  • Page 269 PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation ACCEPT 0.0.0.0/0 0.0.0.0/0 tcp spt:5000 ACCEPT 0.0.0.0/0 0.0.0.0/0 tcp dpt:5000 2. Add the jump setting for the PSA-MMB_LAN chain to INPUT and OUTPUT chains. Make the setting such that there are no interruptions by an existing REJECT setting in an INPUT or OUTPUT chain or by a user definition chain.
  • Page 270: Installing A Psa Update

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation ACCEPT icmp -- 0.0.0.0/0 0.0.0.0/0 icmp type 8 ACCEPT icmp -- 0.0.0.0/0 0.0.0.0/0 icmp type 0 ACCEPT 0.0.0.0/0 0.0.0.0/0 udp dpt:161 ACCEPT 0.0.0.0/0 0.0.0.0/0 udp spt:161 ACCEPT 0.0.0.0/0 0.0.0.0/0...
  • Page 271: Manually Installing Psa (Windows Server 2003)

    For details on the command, see 4.8 SNMP Security Setting Command (setsnmpsec) in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). - You will be changing the SNMP Service security setting from [Accept SNMP packets from any host] to [Accept SNMP packets from these hosts].
  • Page 272: Checks Before Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation - If the set value of the following registry key is less than 20000 (20 seconds), the system may hang during operating system shutdown. Be sure to set a value equal to or greater than 20000 (20 seconds). The default is 20000.
  • Page 273: Installing Psa

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation B.2.3 Installing PSA Install the PSA package. Prepare the ServerView Suite DVD supplied with the main unit. Operations 1. Execute Tools\General\PSA\fjpsaxxxx.exe (xxxx: Version number). The following window appears for installation preparations.
  • Page 274: Figure B.2 Setup Window

    FIGURE B.2 Setup window 3. Specify the installation destination. Then, click the [Next] button. The default installation path for PSA is Program Files\Fujitsu or Program Files(x86)\Fujitsu. To change the installation destination, click the [Browse] button and specify another installation destination.
  • Page 275: Automatic Configuration During Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation FIGURE B.4 Setup complete window 5. You may need to restart your computer. If so, a confirmation dialog box appears. The dialog box asks whether you want to restart the computer immediately.
  • Page 276: Settings After Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation - With [Accept SNMP packets from any host] selected: SNMP security is not configured. - With [Accept SNMP packets from these hosts] selected: If neither the MMB IP address nor localhost is set, SNMP security is configured.
  • Page 277: Manually Installing Psa (Windows Server 2008)

    For details on the command, see 4.8 SNMP Security Setting Command (setsnmpsec) in the PRIMEQUEST 1000 Series Tool Reference (C122-E110EN). - You will be changing the SNMP Service security setting from [Accept SNMP packets from any host] to [Accept SNMP packets from these hosts].
  • Page 278: Checks Before Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation You can use the above registry key to specify the wait time (ms) before the service is terminated in the shutdown sequence. - The event log may have the following message recorded during PSA startup. It does not indicate any operational problem.
  • Page 279: Installing Psa

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation FIGURE B.5 Select Features window B.3.3 Installing PSA Install the PSA package. Prepare the ServerView Suite DVD supplied with the main unit. Operations 1. Execute Tools\General\PSA\fjpsaxxxx.exe (xxxx: Version number).
  • Page 280: Figure B.6 Preparing To Install Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation FIGURE B.6 Preparing to Install window 2. The following window appears when installation preparations are completed. Click the [Next] button to proceed. FIGURE B.7 Setup window 3. Specify the installation destination. Then, click the [Next] button.
  • Page 281: Figure B.8 Select Features Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation The default installation path for PSA is Program Files\Fujitsu or Program Files(x86)\Fujitsu. To change the installation destination, click the [Browse] button and specify another installation destination. FIGURE B.8 Select Features window 4.
  • Page 282: Automatic Configuration During Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation FIGURE B.9 Installation complete window B.3.4 Automatic configuration during PSA installation This section describes the values automatically set for PSA operation during PSA installation. Service settings - PRIMEQUEST Server Agent...
  • Page 283: Settings After Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation B.3.5 Settings after PSA installation This section describes the settings for items after PSA installation. Setting the destinations of traps from a partition Setting the destinations of traps and e-mail via the MMB...
  • Page 284 PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation C122-E107-09EN...
  • Page 285: Appendix C Software (Links)

    APPENDIX C Software (Links) For details on the software bundled with the PRIMEQUEST 1000 series hardware, see 3.3 Bundled Software in the PRIMEQUEST 1000 Series General Description (C122-B022EN). C.1 General Description and Types of Bundled Software ..
  • Page 286: General Description And Types Of Bundled Software

    PRIMEQUEST 1000 Series Installation Manual APPENDIX C Software (Links) General Description and Types of Bundled Software See 3.3 Bundled Software in the PRIMEQUEST 1000 Series General Description (C122-B022EN). C122-E107-09EN...
  • Page 287: Appendix D Configuring The San Boot Environment

    APPENDIX D Configuring the SAN Boot Environment For details on configuring the SAN boot environment, see the PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual (C122-E155EN).
  • Page 288: Appendix E Notes On Vmware Installation

    APPENDIX E Notes on VMware Installation This appendix describes how to install VMware vSphere, using a RAID environment configured in built-in hard disks as an example. It also provides notes on installation. VMware vSphere is referred to below as VMware 4.x, VMware 5.x, or VMware.
  • Page 289: Building A Raid Environment Using Vmware 4.X Built-In Disks

    APPENDIX E Notes on VMware Installation Building a RAID Environment Using VMware 4.x Built-in Disks The PRIMEQUEST 1000 series supports RAID 0, RAID 1, RAID 1E, RAID 5, RAID 6, and RAID 10 that use built-in hard disks. For details on building a RAID configuration using built-in hard disks, see the MegaRAID SAS Software, the MegaRAID SAS Device Driver Installation, and the Modular RAID Controller Installation Guide.
  • Page 290: Notes On Vmware 4.X Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation Notes on VMware 4.x Installation Install VMware 4.x by following the instructions in the VMware vSphere 4.x Software Handbook. For details on the VMware 4.x information and procedures that you need to know for PRIMEQUEST system configuration, contact the distributor where you purchased your product, or your sales representative.
  • Page 291: Figure E.2 [Watchdog] Tab In The Vmware 4.X Software Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation - Enter a value between 1 and 100 minutes for [Timeout]. FIGURE E.2 [Watchdog] tab in the VMware 4.x software window 6. Enter your user name and password, and press the [Enter] key.
  • Page 292: Figure E.4 [Software Watchdog] Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation FIGURE E.4 [Software Watchdog] window C122-E107-09EN...
  • Page 293: Installing Vmware 4.X Bundled Software

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation Installing VMware 4.x Bundled Software The bundled software is stored in ServerView Suite DVD1. Copy the files from ServerView SuiteDVD1 and use them. E.3.1 Installing ServerView Agent Install ServerView Agent by referring to the following manuals: - ServerView Suite ServerView Operations Manager V4.92...
  • Page 294: Installing Vmware 4.X Hrm/Server (Primequest)

    APPENDIX E Notes on VMware Installation 1. Start the terminal with root privileges. 2. Mount ServerView Suite DVD1. 3. Copy the RAS support service module to any directory of the PRIMEQUEST 1000 series, and extract it. # cp MNT/SVSLocalTools/Japanese/RASAssist/Linux/\ LinuxRAS.tgz /tmp # cd /tmp # tar xvzf LinuxRAS.tgz...
  • Page 295 - HRM/SR_Linux/FJSVhrmsr.tgz is available 1. Start the terminal with root privileges. 2. Mount ServerView Suite DVD1. 3. Copy the HRM/server module to any directory of the PRIMEQUEST 1000 series server. Then, expand the files. # cp MNT/SVSLocalTools/Japanese/HRM/SR_Linux/ \ FJSVhrmsr.tgz /tmp MNT is the mount point.
  • Page 296: Installing Vmware 4.X Psa

    PSA is provided only with the PRIMEQUEST 1800E. 1. Start the terminal with root privileges. 2. Mount ServerView Suite DVD1. 3. Copy the PSA module to any directory of the PRIMEQUEST 1000 series server. Then, expand the files. # cp MNT/SVSLocalTools/Japanese/PSA/SR_Linux/\ FJSVpsa-XXXRHEL5.tgz /tmp * MNT is the mount point.
  • Page 297: Installing Svmco

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation # cd /tmp # tar xvzf FJSVpsa-XXXRHEL5.tar.gz 4. Execute the following command. # cd FJSVpsa ./INSTALL.sh -SVIM 5. After the installation of PSA, make the required settings. For details on the setting method, see PSA Setting Procedure for VMware and 6.2 Configuring PSA (Linux: Red Hat Enterprise...
  • Page 298: Settings After Vmware 4.X Psa Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation Settings after VMware 4.x PSA Installation The settings after PSA installation for VMware 4.x partly differ from those for RHEL. This section describes only the different parts. For details on the parts of the setting procedure that are the same as those for RHEL, see the following.
  • Page 299: Figure E.5 Network Configuration Immediately After Installation Of Os

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation FIGURE E.5 Network configuration immediately after installation of OS Remark For details on each command used in the settings below, use man for confirmation. Note Do not set the host name before setting the IP address of vswif0, which exists by default immediately after the installation of the operating system.
  • Page 300 PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation \: This indicates that there is no line feed. In the above example, vmnic0 is used for the PSA-to-MMB communication LAN, and vmnic1is used for the management LAN. Configuring the management LAN 1.
  • Page 301 PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation PortGroup Name VLAN ID Used Ports Uplinks VM Network Service Console 0 Execute the esxcfg-vswitch command to connect the physical adapter vmnic1 to vSwitch0. # esxcfg-vswitch -L vmnic1 vSwitch0...
  • Page 302 PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation PortGroup Name VLAN ID Used Ports Uplinks \: This indicates that there is no line feed. 2. Execute the esxcfg-vswtich command to connect the physical adapter vmnic0 to the virtual switch.
  • Page 303: Table E.2 Ip Addresses To Be Set For Virtual Ports

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation TABLE E.2 IP addresses to be set for virtual ports Partition number IP address Subnet mask 172.30.0.2 255.255.255.0 172.30.0.3 172.30.0.4 172.30.0.5 <Example with the partition number of #2 and the PSA-MMB port group of vswif1>...
  • Page 304: Configuring The Firewall

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation FIGURE E.6 Network configuration after setup E.4.2 Configuring the firewall This section describes how to configure the firewall for PSA operation. For PSA, the following ports must be open.
  • Page 305: Configuring The Default Gateway

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation #esxcfg-firewall -q Opened ports: SNMP : port 161 udp.in PSA-MMB : port 5000 tcp.out E.4.3 Configuring the default gateway Configure the default gateway when installing the operating system. If the default gateway is not configured for some reason, make this setting.
  • Page 306: Retrieving Vmware 4.X Psa Maintenance Information

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation 5. Click the [Routing] tab, and make the [Default gateway] setting in the [Service Console] area. Then click the [OK] button. FIGURE E.8 [DNS and Routing Configuration] dialog box Note For details on VMware vSphere 4.x Client, see the manual of VMware 4.x.
  • Page 307: Notes On Vmware 4.X Psa

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation In VMware 4.x, the core file is output in /var/core, and is not automatically deleted. After executing the vm-support command, we recommend deleting the core file as required. E.4.5 Notes on VMware 4.x PSA...
  • Page 308: Settings After Vmware 4.X Svmco Installation

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation Settings after VMware 4.x SVmco Installation The settings are required for SVmco operation. For details on the SVmco settings, see the ServerView Mission Critical Option user manual. Contact your sales representative for inquiries about the ServerView manuals.
  • Page 309: Building A Raid Environment Using Vmware 5.X Built-In Disks

    APPENDIX E Notes on VMware Installation Building a RAID Environment Using VMware 5.x Built-in Disks The PRIMEQUEST 1000 series supports RAID 0, RAID 1, RAID 1E, RAID 5, RAID 6, and RAID 10 that use built-in hard disks. For details on building a RAID configuration using built-in hard disks, see the MegaRAID SAS Software, the MegaRAID SAS Device Driver Installation, and the Modular RAID Controller Installation Guide.
  • Page 310: Installing Vmware 5.X Bundled Software

    PRIMEQUEST 1000 Series Installation Manual APPENDIX E Notes on VMware Installation Installing VMware 5.x Bundled Software The bundled software is stored in ServerView Suite DVD1. Copy the files from ServerView SuiteDVD1 and use them. The bundled software required for VMware vSphere 5 comprises the following.
  • Page 311: Appendix F Setting Up The Ntp Server (Windows)

    APPENDIX F Setting up the NTP Server (Windows) This appendix describes how to specify and set of an NTP server for a specific Windows operating system. This appendix is not needed for Active Directory member servers. Active Directory member servers automatically synchronize the system clock with the domain controller.
  • Page 312: Overview Of Ntp Client Settings

    In the PRIMEQUEST 1000 series, the system time of a partition is kept in the Home SB. Therefore, if the Home SB of a partition is replaced during maintenance or switched by the reserved SB function, the system time of the partition may become incorrect.
  • Page 313 PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) Task name Task description Target OS Event Task Register the following in Task Scheduler to synchronize with the Windows Server 2008 Settings System time when the time can be acquired from an NTP server: Windows Server 2008 R2 Log: "System", Source: "Time-Service", ID:37...
  • Page 314: Ntp Settings In Windows Server 2003

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) NTP Settings in Windows Server 2003 The procedures in this chapter require Administrator privileges. All screenshots are display examples, and the actually displayed contents vary depending on the system configuration and other factors.
  • Page 315: Figure F.3 [Run] Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.3 [Run] window 2. Open the following key, and set 900 for the SpecialPollInterval value. HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time \TimeProviders\NtpClient "SpetcialPollInterval" Type: REG_DWORD, Data: 900 (decimal) FIGURE F.4 [Registry Editor] window 3.
  • Page 316: Figure F.5 [Services] Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.5 [Services] window 5. Right-click the Windows Time service. Select [Restart] from the context menu. C122-E107-09EN...
  • Page 317: Ntp Settings In Windows Server 2008

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) NTP Settings in Windows Server 2008 The procedures in this chapter require Administrator privileges. All screenshots are display examples, and the actually displayed contents vary depending on the system configuration and other factors.
  • Page 318: Synchronization Interval Setting

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.8 [Internet Time Settings] window 4. Click the [OK] button to close the [Internet Time Settings] dialog box. 5. Click the [OK] button to close the [Date and Time] dialog box.
  • Page 319: Event Task Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) 4. Open [Start] - [Administrative Tools] - [Services]. FIGURE F.11 [Services] window 5. Right-click the Windows Time service. Select [Restart] from the context menu. F.3.3 Event Task Settings 1.
  • Page 320: Figure F.13 [Create Basic Task Wizard] Window (Create A Basic Task)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.13 [Create Basic Task Wizard] window (Create a Basic Task) 4. Select "When a specific event is logged" on the [Task Trigger] screen. Click the [Next] button.
  • Page 321: Figure F.16 [Create Basic Task Wizard] Window (Action)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) 6. Select "Start a program" on the [Action] screen. Click the [Next] button. FIGURE F.16 [Create Basic Task Wizard] window (Action) 7. Set the following parameters on the [Start a Program] screen.
  • Page 322: Figure F.19 [Properties] Dialog Box

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) 9. Click the [Change User or Group] button in the [Properties] dialog box. FIGURE F.19 [Properties] dialog box 10. [Select User or Group] dialog box appears. Set the following parameter.
  • Page 323: Ntp Settings In Windows Server 2008 R2

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) NTP Settings in Windows Server 2008 R2 The procedures in this chapter require Administrator privileges. All screenshots are display examples, and the actually displayed contents vary depending on the system configuration and other factors.
  • Page 324: Synchronization Interval And Startup Settings Of Ntp Service

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) - [Server]: Enter an NTP server name. FIGURE F.23 [Internet Time Settings] window 4. Click the [OK] button to close the [Internet Time Settings] dialog box. 5. Click the [OK] button to close the [Date and Time] dialog box.
  • Page 325: Event Task Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) 4. Open [Start] - [Administrative Tools] - [Services]. FIGURE F.26 [Services] window 5. Right-click the Windows Time service. Select [Properties] from the context menu. 6. Set "Automatic (Delayed Start)" in [Startup Type] in the [Windows Time Properties] dialog box.
  • Page 326: Figure F.28 [Task Scheduler] Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.28 [Task Scheduler] window 2. Select [Create Basic Task] at the right of the window. [Create Basic Task Wizard] appears. 3. Enter a chosen task name in [Name] on the [Create a Basic Task] screen, and click the [Next] button.
  • Page 327: Figure F.30 [Create Basic Task Wizard] Window (Task Trigger)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.30 [Create Basic Task Wizard] window (Task Trigger) 5. [When a Specific Event Is Logged] screen appears. Set the following parameters. - [Log]: System - [Source]: Time-Service - [Event ID]: 37 FIGURE F.31 [Create Basic Task Wizard] window (When a Specific Event Is Logged)
  • Page 328: Figure F.32 [Create Basic Task Wizard] Window (Action)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.32 [Create Basic Task Wizard] window (Action) 7. Set the following parameters on the [Start a Program] screen. - [Program/script]: %SystemRoot%\System32\w32tm.exe - [Add arguments] (optional): /resync FIGURE F.33 [Create Basic Task Wizard] window (Start a Program)
  • Page 329: Figure F.34 [Create Basic Task Wizard] Window (Summary)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.34 [Create Basic Task Wizard] window (Summary) Click the [Finish] button. 9. Click the [Change User or Group] button in the [Properties] dialog box. FIGURE F.35 [Properties] dialog box 10.
  • Page 330 PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) 11. Click the [OK] button to close the [Properties] dialog box. C122-E107-09EN...
  • Page 331: Ntp Settings In Windows Server 2012

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) NTP Settings in Windows Server 2012 The procedures in this chapter requireAdministrator privileges. All screenshots are display examples, and the actually displayed contents vary depending on the system configuration and other factors.
  • Page 332: Synchronization Interval And Startup Settings Of Ntp Service

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.38 [Date and Time] window (2) 3. Set the following parameters in the [Internet Time Settings] dialog box. - [Synchronize with an Internet time server]: Check the check box.
  • Page 333: Figure F.40 [Registry Editor] Selection Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.40 [Registry Editor] selection window 2. Open the following key, and set 900 for the SpecialPollInterval value. HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time \TimeProviders\NtpClient "SpetcialPollInterval" Type: REG_DWORD, Data: 900 (decimal) FIGURE F.41 [Registry Editor] window 3.
  • Page 334: Event Task Settings

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) 5. Right-click the Windows Time service. Select [Properties] from the context menu. 6. Set "Automatic (Delayed Start)" in [Startup type] in the [Windows Time Properties] dialog box.
  • Page 335: Figure F.44 [Task Scheduler] Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.44 [Task Scheduler] window 2. Select [Create Basic Task] at the right of the window. [Create Basic Task Wizard] appears. 3. Enter a chosen task name in [Name] on the [Create a Basic Task] screen, and click the [Next] button.
  • Page 336: Figure F.46 [Create Basic Task Wizard] Window (Task Trigger)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.46 [Create Basic Task Wizard] window (Task Trigger) 5. [When a Specific Event Is Logged] screen appears. Set the following parameters. - [Log]: System - [Source]: Time-Service - [Event ID]: 37 FIGURE F.47 [Create Basic Task Wizard] window (When a Specific Event Is Logged)
  • Page 337: Figure F.48 [Create Basic Task Wizard] Window (Action)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.48 [Create Basic Task Wizard] window (Action) 7. Set the following parameters on the [Start a Program] screen. - [Program/script]: %SystemRoot%\w32tm.exe - [Add arguments] (optional): /resync FIGURE F.49 [Create Basic Task Wizard] window (Start a Program)
  • Page 338: Figure F.50 [Create Basic Task Wizard] Window (Summary)

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.50 [Create Basic Task Wizard] window (Summary) Click the [Finish] button. 9. Click the [Change User or Group] button in the [Properties] dialog box. FIGURE F.51 [Properties] dialog box 10.
  • Page 339: Figure F.52 [Select User Or Group] Window

    PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) FIGURE F.52 [Select User or Group] window Click the [OK] button. 11. Click the [OK] button to close the [Properties] dialog box. C122-E107-09EN...
  • Page 340 PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server (Windows) C122-E107-09EN...
  • Page 341: Index

    PRIMEQUEST 1000 Series Installation Manual Index Index [Create Basic Task Wizard] window (Action)..[Access Control] window (example)......Accessories required in main unit installation....[Create Basic Task Wizard] window (Create a Basic Task)... [Add a Port] dialog box (PSA)........[Add a Port] dialog box (SNMP)........
  • Page 342 PRIMEQUEST 1000 Series Installation Manual Index Lists of Settings (Links)..........Packages required for PSA operation (RHEL5).... Packages required for PSA operation (RHEL6).... Packages required for SIRMS operation (RHEL6)..Maintenance status display..........[Partition Configuration] window (example)..[Management LAN Port Configuration] window (example) [Partition Home] window (example)........
  • Page 343 PRIMEQUEST 1000 Series Installation Manual Index Settings automatically added/changed during PSA Work after Operating System Installation (PRIMEQUEST installation........... 1800E2)................Settings for system clock syncronization....... Work before Operating System Installation..... Settings for terminal software.......... Work performed by the user..........Setting Up the Dump Environment (Linux)..

This manual is also suitable for:

Primequest 1800e2Primequest 1800e

Table of Contents