Table 2.9 Displayed And Setting Items In The [Alarm E-Mail Filtering Condition] Window - Fujitsu PRIMEQUEST 500A Series Installation Manual

Table of Contents

Advertisement

2
Select the required items.
If multiple items are selected, they are joined by the AND operator and their sub-
items are joined by the OR operator.

Table 2.9 Displayed and setting items in the [Alarm E-mail Filtering Condition] window

Item
Severity
Partition
Unit
Source
3
Click the [Apply] button.
C122-E001-10EN
Selects the level of Severity to be reported by e-mail. More than one can be
selected.
• [Error]: Important problems such as hardware problems
• [Warning]: Events not always important but likely be a problem in the
future
• [Info]: Normal events such as partition power-on
Selects the target partition for reporting by mail. More than one can be
selected.
Selects a unit to be displayed.
Select [All] or [Specified] with a radio button.
• If [All] is selected, filtering by [Unit] is not done.
• If [Specified] is selected, filtering by unit can be set. Use the check box
to select a unit for which you want events displayed.
Selects the source on which notification e-mail is to be sent.
Select [All] or [Specified] with a radio button.
• [All]: Filtering by source is not done.
• [Specified]: Filtering by source can be set.
2.2 MMB Connection and Setup
Description
Default: All partitions
Default: All errors
Default: [All]
2-25