CHAPTER 4 Work Required After Operating System Installation
Verifying the trap transfer destination setting
To verify the trap transfer destination setting, use the standard net-snmp trap that
would be used to restart snmpd. Check the reception of this trap to verify the transfer
destination setting.
Remarks:A trap receipt application or trap manager must be active at the trap transfer
Restart snmpd by executing the following command on the trap transfer source
machine:
# /etc/rc.d/init.d/snmpd restart
As a result, the trap receipt application at the trap transfer destination receives the
"ColdStart" standard net-snmp trap.
For example, if the trap transfer destination is a Linux machine, the following
message is added to syslog when snmptrapd receives the trap, and this indicates that
the trap transfer destination can correctly receive such traps.
Aug 17 12:00:53 shaka snmptrapd[2600]: 2005-08-17 12:00:53
pq-server.fujitsu.com [192.168.0.162] (via 192.168.0.162) TRAP, SNMP v1,
community public NET-SNMP-MIB::netSnmpAgentOIDs.10 Cold Start Trap (0)
Uptime: 0:00:00.17
4.3.6
Setting the destinations of trap and e-mail sending via the MMB
Notes:
The destinations of trap and e-mail sending via the MMB can be set with the MMB
Web UI.
See
Section 5.1.2, "System SNMP setting."
Section 2.2.3.5, "SMTP settings."
4-32
destination to ensure that net-snmp standard traps can be received.
Make this setting only if required.
The setting is required for linkage with operation management software
(such as Systemwalker).
for the MMB trap destination. See
for the e-mail destination.