Appendix C Power Control
C.3.2
Partition power-off procedures
This section explains the partition power-off procedures.
Notes:
• A partition in which Windows is installed may not be shut down when the
shutdown function is executed from the MMB Web-UI. To turn off power to the
partition, use the Windows shutdown function. For details on the Windows
shutdown function, see the PRIMEQUEST 580A/540A/520A/500/400 Series
Reference Manual: Basic Operation/GUI/Commands (C122-E003EN).
• If the following condition occurs, contact a Fujitsu certified service engineer:
Also, do not execute [Reset] or [Force Power Off] for a partition until the problem
is removed.
[Power off], [Reset], or [Force Power Off] is executed for a partition or a
shutdown is executed from the operating system, and, as a result, "Error" is
displayed for [Status] in the MMB Web-UI window (information frame).
Furthermore, an attempt to display the status of each component in the MMB
Web-UI window causes "Read Error" to be displayed for [Part Number] or [Serial
Number].
Procedure
1
Log in to MMB Web-UI.
The MMB Web-UI window is displayed.
2
Click [Partition]
The [Power Control] window is displayed.
The # column shows partitions numbers.
C-18
[Power Control] from the MMB menu.
Figure C.9 [Power Control] window