CHAPTER 4 Work Required After Operating System Installation
2
Enter necessary data and click the [Apply] button.
Table 4.5 Displayed and setting items in the [Watchdog] window
Item
Software Watchdog
4-104
Watchdog
Specify whether to enable Software Watchdog
monitoring.
[Disable]: Do not monitor.
[Enable]: Monitor.
TimeOut
Specify the time-out value in seconds when
Software Watchdog monitoring is enabled.
Specification range: 60 - 6000 seconds
(This option can be specified only when
[Watchdog] is [Enable].)
Watchdog
Select the action to be taken if recovery fails after
Action
time-out occurs. Select one from the drop-down
list.
• [No Action]: Do nothing.
however.
• [Reset]: Reset the partition.
• [Power Off]: Forcibly turn off the partition
without executing the normal end processing for
the OS (shutdown).
• [Power Cycle]: Forcibly turn off the partition
and then turn it on again.
• [INIT]: Cause an INIT interrupt to the partition.
(This option can be specified only when
[Watchdog] is [Enable].)
Description
Default: [Disable]
Do SEL output,
Default: [No Action]
Default: 3600