Appendix C Power Control
Explanation of the [System Power Control] window
Table C.1 Displayed and setting items in the [System Power Control] window
Power
Power On the Chassis only
(PRIMEQUEST 580A/540A/
580/540/480/440 only)
Power Off – the Chassis (all
partition(s) will be
automatically shutdown).
Force Power Off
C.1.2.2 Power-off procedure for the entire system
Data destruction
Before shutting down power, make sure the following events have occurred;
otherwise, data may be destroyed:
All applications have completed processing.
No user is using a component.
Note:
Remarks: The procedures described below show sample screenshots of windows
Procedure
1
Log in to MMB Web-UI.
The MMB Web-UI window is displayed.
2
Click [System]
The [System Power Control] window is displayed.
C-10
Item
On all
partition(s)
A partition in which Windows is installed may not be shut down when the
shutdown function is executed from the MMB Web-UI. To turn off power
to the partition, use the Windows shutdown function. For details on the
Windows shutdown function, see the PRIMEQUEST 580A/540A/520A/
500/400 Series Reference Manual: Basic Operation/GUI/Commands
(C122-E003EN).
displayed for the PRIMEQUEST 580A/540A/580/540/480/440.
[System Power Control] from the MMB menu.
Description
Power to every partition is turned on.
If this item is selected while only cabinet power is on,
power to every partition is turned on.
Power to components other than the SB and IO Unit
is turned on.
This power-on operation includes the GSWB.
Power to all partitions and cabinets is turned off.
If you select this option in the power-off state,
nothing happens.
Power is turned off without shutting down partitions.
C122-E001-10EN