FUJITSU Server PRIMEQUEST 2000 Series REMCS Installation Manual CA92344-0542-02...
Page 2
Preface Preface This manual describes the functions and features of the PRIMEQUEST 2000 series. The manual is intended for system administrators. For details on the regulatory compliance statements and safety precautions, see the PRIMEQUEST 2000 Series Safety and Regulatory Information (CA92344-0523).
Preface Revision History Edition Date Revised location (type) (*1) Description - The edition is initialized to "01" 2014-08-12 All pages for changing manual code Added notes 2014-10-07 CHAPTER 3 REMCS settings *1: Chapter, section, and item numbers in the "Revised location" column refer to those in the latest edition of the document.
Similarly, one space line is inserted before and after the alert statement. Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu. Customers must not perform these tasks under any circumstances.
Page 5
Preface Warning label location (the main cabinet top) CA92344-0542-02...
Page 6
Preface Warning label location (the main cabinet left) Front Warning label location (PCI_Box) CA92344-0542-02...
For stable operation of the PRIMEQUEST 2000 series server, use only a Fujitsu-certified optional product as an added option. Note that the PRIMEQUEST 2000 series server is not guaranteed to operate with any optional product not certified by Fujitsu. Maintenance Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu.
Be sure to keep this manual in a safe and convenient location for quick reference. Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage. Be sure to use the product according to the instructions in this manual.
Page 9
Includes the specifications of and the installation location CA92344-0535 Hardware Installation Manual requirements for the PRIMEQUEST 2000 series. PRIMEQUEST 2000 Series Describes how to set up the PRIMEQUEST 2000 series CA92344-0536 Installation Manual server, including the steps for installation preparation, initialization, and software installation.
Page 10
Preface Related manuals The following manuals relate to the PRIMEQUEST 2000 series. You can access these manuals at the following site: http://www.fujitsu.com/global/services/computing/server/primequest/Contact your sales representative for inquiries about the ServerView manuals. Title Description ServerView Suite ServerView Operations Describes how to install and start ServerView Operations Manager Manager Quick Installation (Windows) in a Windows environment.
Page 11
Preface Abbreviations This manual uses the following product name abbreviations. Formal product name Abbreviation Microsoft ® Windows Server ® 2012 R2 Datacenter Windows, Windows Server 2012 Microsoft ® Windows Server ® 2012 R2 Standard Microsoft ® Windows Server ® 2012 Datacenter Microsoft ®...
The PDF file of this manual is intended for display using Adobe® Reader® in single page viewing mode at 100% zoom. This manual shall not be reproduced or copied without the permission of Fujitsu Limited. Copyright 2014 FUJITSU LIMITED CA92344-0542-02...
Preface Contents Preface ..........................................i CHAPTER 1 REMCS Service Overview ..............................1 Purpose of REMCS Service ................................. 1 REMCS Linkage Overview ................................1 1.2.1 Components implementing the REMCS function ........................1 1.2.2 Installing the REMCS function..............................2 1.2.3 Connection configurations supported by the REMCS function ....................2 CHAPTER 2 Before Using the REMCS Service ............................
Preface CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings ........................ 44 Overview of REMCS Service Detail Settings ..........................44 Detail Environment Settings ............................... 45 Selecting REMCS Center ................................48 Select Language ..................................48 Machine Name Display Change ..............................49 Deleting the Personal Information .............................. 50 Display of certificate ..................................
Page 15
Preface Figures FIGURE 1.1 REMCS linkage ................................... 1 FIGURE 2.1 Internet connection (using the network connected to the user port) ................. 4 FIGURE 2.2 Internet connection (using REMCS port) ........................... 4 FIGURE 2.3 P-P connection (ISDN: e-mail) (using the network connected to a USER port) .............. 5 FIGURE 2.4 P-P connection (ISDN: e-mail) (using the REMCS port) ....................
Page 16
Preface FIGURE 4.18 [Sending Hardware Configuration Information] window ....................42 FIGURE 4.19 [Sending Software Configuration Information] window ....................43 FIGURE 5.1 FE operation initial window ............................... 44 FIGURE 5.2 [Environment settings] window in case of internet connection (only mail) ..............45 FIGURE 5.3 [Environment settings] window in case of P-P connection .....................
Page 17
Preface Tables TABLE 3.1 Input items for the [Internet(Mail Only) connection environment settings] window ............12 TABLE 3.2 Input items for the [Point-to-Point Connection environment settings] window ..............13 TABLE 3.3 Input items for the [Periodical Connection settings] window ..................... 14 TABLE 3.4 Input items for the [Customer Information] window ......................
Page 18
Preface TABLE 6.34 Messages in the [Replacement to the previous certificate] window ................65 TABLE 6.35 Messages in the [Display of certificate] window ......................65 TABLE 6.36 List of communication error messages (SMTP communication) ................... 65 TABLE 8.1 REMCS message window ..............................69 CA92344-0542-02 xvii...
The REMCS service connects your PRIMEQUEST 2000 Series to the REMCS Center, a total support center for Fujitsu customers, through the Internet or P-P (point to point) connection to enable the system to send server configuration information and automatically report failures when they occur. The REMCS service is thus intended to facilitate prompt responses and solutions to problems.
Installation of Operating System and bundled software in the PRIMEQUEST 2000 Series Installation Manual (CA92344-0536 A case without SVIM The following packages are downloaded from the Web site of Fujitsu, and it installs it according to attached README. ・SIRMS ・REMCS Option 1.2.3 Connection configurations supported by the REMCS function...
The connection configuration to be used must be determined beforehand. The PRIMEQUEST 2000 Series supports the following connection configurations. All of these connection configurations use only SMTP to communicate with the REMCS Center. Internet connection (e-mail) P-P connection (ISDN: e-mail) Field engineers make the setting for connecting to the REMCS Center.
CHAPTER 2 Before Using the REMCS Service 2.2 Connection Configuration for Connecting to the REMCS Center FIGURE 2.1 Internet connection (using the network connected to the user port) Using a network not connected to the user port FIGURE 2.2 Internet connection (using REMCS port) shows a configuration that uses the REMCS port to connect to a network other than that connected to the user port.
CHAPTER 2 Before Using the REMCS Service 2.2 Connection Configuration for Connecting to the REMCS Center FIGURE 2.3 P-P connection (ISDN: e-mail) (using the network connected to a USER port) Through a network that is not connected to a USER port FIGURE 2.4 P-P connection (ISDN: e-mail) (using the REMCS port) shows a configuration that uses the REMCS port to connect to a network other than the network connected to a USER port.
CHAPTER 3 REMCS Service Start Procedure 3.1 Start Procedure Overview CHAPTER 3 REMCS Service Start Procedure This chapter describes the procedure for starting the REMCS service. Start Procedure Overview To start the REMCS service, the user must register with the REMCS Center (registration). Registration means to register customer information with the REMCS Center.
Page 25
CHAPTER 3 REMCS Service Start Procedure 3.1 Start Procedure Overview FIGURE 3.1 REMCS Center registration flow Before registration, prepare the following information. - Warranty (contains your machine model name, check code, and serial number) The warranty is used to confirm that the machine ID displayed at the bottom of the REMCS window is correct.
Display command: Displays the REMCS port settings. show maintenance_ip For details on the commands, see Chapter 2 MMB CLI (Command Line Interface) Operations in the PRIMEQUEST 2000 Series Tool Reference (CA92344-0539). Note Do not perform registration during the maintenance work.
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.2 [Customer Information Registration Instructions] window 1. Click the [Next] button. The window for selecting the REMCS Center to connect to appears. 3.2.2 Setting the connection configuration Select the REMCS Center to connect to in the window shown in FIGURE 3.3 [Selecting REMCS Center] window.
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.3 [Selecting REMCS Center] window 1. Click the [Next] button. The REMCS Center to connect to is registered. Then, the [Initial Settings] window for setting up the environment appears. 3.2.3 Setting up the environment Set up the environment from FIGURE 3.4 [Initial Settings]...
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.4 [Initial Settings] window Newly setting up the environment The procedure for newly setting up the environment is as follows. 1. Select the connection configuration from the following. Internet Connection(Mail Only): The initial setting for the connection configuration P-P Connection(ISDN: Mail Only): Connection via ISDN P-P Connection(VPN: Mail Only): Connection via VPN 2.
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.5 [Internet(Mail Only) connection environment settings] window 1. Enter the values for the following items. TABLE 3.1 Input items for the [Internet(Mail Only) connection environment settings] window Item Description SMTP Server Enter the SMTP server name or IP address in single-byte alphanumeric characters and symbols.
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration When the connection configuration is [P-P Connection(ISDN: Mail Only)] or [P-P Connection(VPN:Mail Only)] If you selected [P-P Connection(ISDN: Mail Only)] or [P-P Connection(VPN: Mail Only)] in the window shown FIGURE 3.4 [Initial Settings] window, the window shown in FIGURE 3.6 [Point-to-Point Connection environment settings] window...
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.7 [Periodical Connection settings] window 1. Specify the values for the following items. TABLE 3.3 Input items for the [Periodical Connection settings] window Item Description current schedule of The initial values are [Every week] and [10:00] to [15:00]. Specify Periodic Connection values if you need to change the setting.
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.8 [Customer Information] window You can use the following characters and symbols for input. E-mail addresses must include, but cannot begin or end with, an @ mark. Also, the character that follows the @ mark must not be a dot (.).
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration characters). Specify the country name with the code in the A2 column of ISO-3166 Code Table (two letters). For a country not specified in the table, specify 99. Machine Optional Enter the machine installation site (not Installation required if it is the same as the [Address]...
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration After the customer information is registered, the window shown in FIGURE 3.10 [Information Transmit Agreement] window appears. This window also appears when you click the [Auto Setting] button in the window for restoring setting information to perform automatic setting.
CHAPTER 3 REMCS Service Start Procedure 3.2 REMCS Center Registration FIGURE 3.11 [Registration result] window 1. Click the [Next] button to proceed to 3.2.7 Checking the connection. 3.2.7 Checking the connection 1. The window shown in FIGURE 3.12 [Connection check] window appears.
CHAPTER 3 REMCS Service Start Procedure 3.3 Importing the Registration Information Notification of the result to the installer: Specify whether to report the result to the installer. If you select notification, set the installer's e-mail address in [E-mail address for receiving results]. 2.
CHAPTER 3 REMCS Service Start Procedure 3.3 Importing the Registration Information FIGURE 3.14 [Importation of the REMCS settings] window 1. In the PC or file server running the Web browser, specify the following files that were previously backed up and saved. Environment information file: Browse an rm_bkenv.def file.
CHAPTER 3 REMCS Service Start Procedure 3.3 Importing the Registration Information FIGURE 3.16 [Connection check information] window Notification of the result to the administrator Specify whether to report the result to the administrator. The administrator e-mail address in the imported customer information is displayed as your administrator e-mail address. Notification of the result to the installer Specify whether to report the result to the installer.
CHAPTER 3 REMCS Service Start Procedure 3.4 Replacing the S/MIME certificate during the initialization work FIGURE 3.18 [Automatic registration state] window 6. Click the [OK] button. After the registration is completed, the window shown in FIGURE 4.1 [REMCS initial] window appears.
CHAPTER 3 REMCS Service Start Procedure 3.4 Replacing the S/MIME certificate during the initialization work FIGURE 3.20 [Confirmation of certificate] window (during initialization work) 3. Click the [Next] button to output the following confirmation message. "The certificates will be replaced. Once the replacement of certificates proceeds, the report to the REMCS center will not be done until connected confirmation is completed.
CHAPTER 3 REMCS Service Start Procedure 3.5 The notes about the importing and the automatic registration procedures of the REMCS settings The notes about the importing and the automatic registration procedures of the REMCS settings The following notes are about the importing and the automatic registration procedures of the REMCS settings along with the support of the SMTP over SSL connection with PRIMEQUEST 2000.
Page 43
CHAPTER 3 REMCS Service Start Procedure 3.5 The notes about the importing and the automatic registration procedures of the REMCS settings Type of encrypted [case1] connection is N *1 "STARTTLS" or "SSL/TLS" ESAT (Mail SMTP over V03L01 Only) or less Internet unavailable A *5...
Page 44
CHAPTER 3 REMCS Service Start Procedure 3.5 The notes about the importing and the automatic registration procedures of the REMCS settings The following cases(1-3) show the trouble's sequences. < Term definition > ・SMTPs unused : "Type of encrypted connection" is set "None". ・SMTPs use : "Type of encrypted connection"...
Page 45
CHAPTER 3 REMCS Service Start Procedure 3.5 The notes about the importing and the automatic registration procedures of the REMCS settings [Case2] In the condition that PRIMEQUEST 2000 is connected SMTP Server A by 2 with the setting 1. If the setting of 3 is imported by 4, "SMTPs use" as 5 is not changed because of not outputting "SMTPs unused"...
Page 46
CHAPTER 3 REMCS Service Start Procedure 3.5 The notes about the importing and the automatic registration procedures of the REMCS settings [Case3] In the condition that PRIMEQUEST 2000(Import side) is connected SMTP Server B by 2 with the setting 1. If the setting of 3 is imported by 4, "SMTPs use"...
CHAPTER 4 REMCS Service Operations 4.1 REMCS Operations Overview CHAPTER 4 REMCS Service Operations This chapter describes how to operate the REMCS service. REMCS Operations Overview When the REMCS Center registration is completed or cancelled, the window shown in FIGURE 4.1 [REMCS initial] window appears.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu HW Config. Info. Sends the software configuration information. Exit Exits the REMCS operations and closes the browser window. REMCS Service Menu This section describes the REMCS service menu items. 4.2.1 Customer Information update Use this menu item to confirm the customer information entered on registration or to change the information such as the administrator name or company address.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu Connection environment settings] window appears. For details on how to operate the windows, see CHAPTER 3 REMCS Service Start Procedure. FIGURE 4.2 [Internet (Mail Only) connection environment settings] window FIGURE 4.3 [Point-to-Point Connection environment settings] window Confirm the information.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.4 [Periodical Connection settings] window After changing the periodic connection schedule, click the [Next] button. A connection check is performed to report the schedule to the REMCS Center. When the processing completes, you will be returned to FIGURE 4.1 [REMCS initial] window.
Page 51
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.5 [Exportation of the REMCS settings] window CA92344-0542-02...
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu 4.2.6 Connection type change Use this menu item to change the current connection configuration to another configuration. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [Connection type change].
Page 53
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.7 [Display of certificate] window (with certificate not replaced) Certificate display when the certificate has been displayed (certificate in use) Select [Certificate under use] and then click the [Display] button. FIGURE 4.8 [Display of certificate] window (during use of certificate that has been replaced) Certificate display for certificate that has been replaced (previous certificate) Select [The previous certificate] and then click the [Display] button.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.9 [Display of certificate] window (Certificate that has been displayed – previous certificate) To confirm and exit, click the [End] button. Click the [End] button to return to the window shown in FIGURE 4.1 [REMCS initial] window.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu Specify the certificate file and then click the [Next] button. FIGURE 4.11 [Confirmation of certificate] window Confirm the display contents and, if they are acceptable, click the [Next] button. If you do not intend to replace a certificate, click the [Cancel] button. The following confirmation message is displayed."The certificates will be replaced.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu Confirm the content of the <<Restored certificate>> and then click the [Next] button. If you do not wish to restore the certificate, click the [Cancel] button. The following confirmation message appears. "The certificates will be replaced. Once the replacement of certificates proceeds, the report to the REMCS center will not be done until connected confirmation is completed.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.14 [Connection check] window (with personal information deleted) 3. The window shown in FIGURE 4.15 [Result of connection check] window appears. Click the [OK] button. You will be returned to the window shown in FIGURE 4.1 [REMCS initial] window.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.15 [Result of connection check] window The e-mail addresses displayed in the [Connection check] window as the receivers of the connection results receive an e-mail notification of the completed connection check. 4.2.11 Temporary Disconnection Use this menu item to temporarily disconnect from the REMCS Center.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.16 [Temporary Disconnection] window 4.2.12 Reconnection Use this menu item to re-establish the connection with the REMCS Center after a temporary disconnection. If the server operating status has been shown as [DISCONNECT], it becomes [ACTIVE]. f the status has been in [MAINTAIN/DISCONNECT], it becomes [MAINTAIN].
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu FIGURE 4.17 [Reconnection] window 4.2.13 HW Config. Info. Use this menu item to send the hardware configuration information of the server to the REMCS Center. From the menu in the window shown in FIGURE 4.1 [REMCS initial] window, click [HW Config.
CHAPTER 4 REMCS Service Operations 4.2 REMCS Service Menu 1. Click the [Send] button. A confirmation dialog box appears. Send the software configuration information to the REMCS Center. After processing completes, a pop-up window appears with the results. Then, the window shown in FIGURE 4.1 [REMCS initial] window appears.
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.1 Overview of REMCS Service Detail Settings CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings This chapter describes the detail settings of the REMCS service. Overview of REMCS Service Detail Settings REMCS Service Detail Settings are used to make detailed settings such as the transmission retry count and timeout triggers for avoiding transmission problems.
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.2 Detail Environment Settings Detail Environment Settings This item is used to change the communication environment settings for Internet use. The displayed window contents depend on the authentication type of the connection configuration as shown FIGURE 5.2 [Environment settings] window in case of internet connection (only mail) FIGURE 5.3 [Environment settings] window in case of P-P...
Page 64
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.2 Detail Environment Settings User ID Required (*1) Enter user ID of authentication server in single-byte numeric number and alphabets. Password Required (*1) Enter password of authentication server in single-byte numeric number and alphabets. Entered values are all displayed as *.
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.2 Detail Environment Settings FIGURE 5.3 [Environment settings] window in case of P-P connection TABLE 5.3 Items in the [Environment settings] window in case of P-P connection Input item Maximum Input Description number of digits E-Mail settings...
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.3 Selecting REMCS Center *1: It is required if you select item except for ‘none’ in dividing method. 1. From the initial window menu of the FE operation, select [Detail environment settings]. Depending on the current setting conditions, FIGURE 5.2 [Environment settings] window in case of internet connection (only mail)
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.5 Machine Name Display Change FIGURE 5.5 [Select language (Japanese or English)] window Machine Name Display Change This item is used for switching the machine name to be displayed by the GUI between the machine ID or machine unique name, which has been specified in the [Customer Information] window.
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.6 Deleting the Personal Information FIGURE 5.6 [Select to Display Machine ID or Machine Unique Name] window Deleting the Personal Information This item is used for deleting the personal information included in the customer information after registration. From the initial window menu of the FE operation, select [Deleting the personal information] to display FIGURE 5.7 [Deleting the personal information] window.
CHAPTER 5 CHAPTER 5 REMCS Service Detail Settings 5.7 Display of certificate エラー! 参照元 1. From the initial window menu of the FE operation, select [Display of certificate] to display が見つかりません。. 2. Click [End] button. FIGURE 5.8 [Display of certificate] window (SSL) CA92344-0542-02...
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows CHAPTER 6 REMCS Messages This chapter describes the major error messages that are displayed in the windows. Messages in REMCS Windows This section describes the messages displayed in the REMCS windows. In the messages, xxx represents a character string such as a returned value that should be replaced when printed out.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows problem is not solved, contact the support center. RMG_0005 Frame data make completed. None. RMG_0006 Failed to get connect mode. (xxx) If the error still occurs when you retry the operation, exit and restart the REMCS window and try again.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows TABLE 6.8 Messages in the [Initial Settings] window Message code Message Action RMG_0001 Failed to get Machine status. (xxx) If the error still occurs when you retry the operation, exit RMG_0002 Failed to make frame screen data.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows problem is not solved, contact the support center. RMG_0210 Personal information deletion frame display None. has been completed. TABLE 6.10 Messages in the [Customer Information Review] window Message code Message Action RMG_0002 Failed to make frame screen data.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows RMG_0042 Internet(Mail Only) connection environment None. setting frame display completed. RMG_0043 Failed to set REMCS environment (Internet Confirm the FQDN or IP connection(Mail only)). (xxx) address of the specified SMTP server. Also check whether the network status is normal.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows RMG_0095 Connection type mismatch. If the error still occurs when you retry the operation, exit and restart the REMCS window and try again. If the problem is not solved, contact the support center. RMG_0181 Invalid E-mail address specified.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows RMG_0006 Failed to get connect mode. (xxx) window and try again. If the problem is not solved, contact the support center. RMG_0015 Invalid entry. Correct the entered value. RMG_0018 Failed to get registration data. (xxx) If the error still occurs when you retry the operation, exit and restart the REMCS...
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows RMG_0001 Failed to get Machine status. (xxx) If the error still occurs when you retry the operation, exit RMG_0002 Failed to make frame screen data. (xxx) and restart the REMCS RMG_0004 Invalid CGI parameter specified.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows problem is not solved, contact the support center. Exportation of the environment information None. RMG_0123 has been completed. Exportation of the customer information has RMG_0124 been completed. RMG_0125 Export customer information to a file. Click the [OK] or [Cancel] button RMG_0126...
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows completed. Temporary disconnection to the REMCS RMG_0061 Center completed. Temporary disconnection frame display RMG_0062 completed. RMG_0063 Reconnection frame display completed. Execute reconnection to the REMCS Center. Click the [OK] or [Cancel] RMG_0064 Are you sure? button.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows RMG_0009 FE initial frame display completed. None. TABLE 6.26 Messages in the [Environment settings] window Message code Message Action Failed to get Machine status.(xxx) If the error still occurs when RMG_0001 \n(MachineID=xxxxxx) you retry the operation, exit and restart the REMCS...
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows and restart the REMCS window and try again. If the problem solved, contact the support center. TABLE 6.28 Messages in the [Select language(Japanese or English)] window Message code Message Action RMG_0002 Failed to make frame screen data.
CHAPTER 6 REMCS Messages 6.1 Messages in REMCS Windows If the error still occurs when you retry the operation, exit and restart the REMCS RMG_0196 Failed to delete personal information.(xxx) window and try again. If the problem is not solved, contact the support center.
CHAPTER 6 REMCS Messages 6.2 Communication Error Messages (SMTP Communication) TABLE 6.34 Messages in the [Replacement to the previous certificate] window Message code Message Action RMG_0001 Failed to get Machine status.(xxx) If the error still occurs when you retry the operation, exit RMG_0002 Failed to make frame screen data.
Page 84
CHAPTER 6 REMCS Messages 6.2 Communication Error Messages (SMTP Communication) server. Please improve environment with reference to the following messages. (Message from the SMTP server) xxxxxxxxxxxxxxxxxxxx RL:xxx,ML:xxx RMG_2005 (SMTP)Unable to connect the specified mail(SMTP) Server. Error was detected during communication to the specified mail (SMTP) server.
CHAPTER 6 REMCS Messages 6.3 Other Error Messages on SMTP server. (Message from the POP3 server) xxxxxxxxxxxxxxxxxxxx RL:xxx,ML:xxx RMG_2012 (SMTP)An error was detected during communication to the specified mail(SMTP) server. The specified SMTP server does not support SMTP AUTH. Or the SMTP server does not support specified auth type.
[System] - [System Event Log] from the MMB Web-UI menu to download the log kept by the MMB. For details of the operation, see Section 1.2.2 [System Event Log] window in the PRIMEQUEST 2000 Series Tool Reference (CA92344-0539). Hand over the downloaded log to a field engineer.
CHAPTER 8 Notes on Using REMCS GUI 8.1 Notes on Using REMCS GUI CHAPTER 8 Notes on Using REMCS GUI This chapter describes the notes on using the REMCS GUI. Notes on Using REMCS GUI The REMCS GUI is displayed in a separate window when the REMCS menu is selected from the MMB Web At this time, if a security software product with a firewall function has been installed on the personal computer or the like used to run the Web browser, it may block cookies or other information from the site being browsed depending on the default settings.
Page 88
CHAPTER 8 Notes on Using REMCS GUI 8.1 Notes on Using REMCS GUI Clicking the [Compulsory REMCS menu opening] button logs you in by forcibly logging out the current login user. Click the [Close] button to close the window. If the time zone setting has been changed from the [MMB Web-UI] window, perform the following operation to update the REMCS Center information: Execute the periodic connection schedule settings.