CHAPTER 4 Work Required After Operating System Installation
Information to be monitored and processing to be performed
Information to be monitored
S.M.A.R.T. performs predictive monitoring for the information types below and
reports when the threshold defined for each of them in S.M.A.R.T. is exceeded.
The threshold for each item depends on the type of disk of each vendor.
- Temperature
- Read error rate
- Write error rate
- Seek error rate
- Spin-up time
- Number of remaining alternate sectors
After monitoring is set, the system periodically (at about six-hour intervals) polls
S.M.A.R.T. on each disk to check for predictive detection.
Processing performed at detection of a predictive sign of error
- Blinks the Fault LED on the relevant disk by repeating a cycle of "four quick
blinks + pause"
- Outputs information posted from S.M.A.R.T. to SYSLOG and reports it
(REMCS/e-mail)
Procedure
1
Click [Partition]
The [S.M.A.R.T.] window is displayed.
2
Select [Enable] or [Disable] and click the [Apply] button.
S.M.A.R.T. Monitoring
4-100
[Partition#x]
Figure 4.48 [S.M.A.R.T.] window
Item
• [Enable]: Enables S.M.A.R.T. monitoring.
• [Disable]: Disables S.M.A.R.T. monitoring.
[PSA]
[Setup]
Description
[S.M.A.R.T.].
Default: [Enable]