Under Maintenance
Reference: If the OS supports the Advanced Configuration and Power Interface
Remarks: After the cabinet power is turned off, it cannot be turned on again for a
C122-E001-10EN
Item
This indicates whether a partition is under maintenance:
[Maintenance]: The partition is under maintenance.
[- (hyphen)]: The partition is not under maintenance.
Partitions under maintenance are excluded from power
control from this window.
Remarks: With the PRIMEQUEST 500A/500 series, the
(ACPI), the power-off operation shuts down the OS and then turns off the
power. However, if the OS does not support ACPI, the power-off
operation turns off the power without shutting down the OS.
Even if the OS supports ACPI, the power-off operation may fail if an
application running on the OS does not support it. This symptom depends
on the specifications of the OS or the applications. For details, see the OS
or application manuals.
certain period of time. During this period, [Power Control] is grayed out
and cannot be selected.
C.3 Powering On and Powering Off Partitions
Description
"Under Maintenance" item may not be
displayed in the [Power Control] window
depending on the MMB firmware version. In
this case, the number of the partition under
maintenance is displayed under "Under
Maintenance" in the information area.