Set Lldp Trap-Interval; Set Lldp Med-Fast-Repeat - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

set lldp trap-interval

Use this command to set the minimum interval between LLDP notifications sent by this device. 
LLDP notifications are sent when a remote system change has been detected.
Syntax
set lldp trap-interval frequency
Parameters
frequency
Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets the minimum interval between LLDP traps to 10 seconds.
C2(rw)->set lldp trap-interval 10

set lldp med-fast-repeat

Network connectivity devices transmit only LLDP TLVs in LLDPDUs until they detect that an 
LLDP‐MED endpoint device has connected to a port. At that point, the network connectivity 
device starts sending LLDP‐MED TLVs at a fast start rate on that port. Use this command to set the 
number of successive LLDPDUs (with LLDP‐MED TLVs) to be sent for one complete fast start 
interval.
Syntax
set lldp med-fast-repeat count
Parameters
count
Defaults
None.
Mode
Switch command, read‐write.
Specifies the minimum time between LLDP trap transmissions, in 
seconds. The value can range from 5 to 3600 seconds. The default 
value is 5 seconds.
Specifies the number of fast start LLDPDUs to be sent when an 
LLDP‐MED endpoint device is detected. Value can range from 1 to 
10. Default is 3.
set lldp trap-interval
SecureStack C2 Configuration Guide 6-23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SecureStack C2 C2G170-24 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

C2h124-24Securestack c2

Table of Contents