show lldp port local-info

show lldp port local-info
Use this command to display the local system information stored for one or more ports. You can 
use this information to detect misconfigurations or incompatibilities between the local port and 
the attached endpoint device (remote port).
Syntax
show lldp port local-info [port-string]
Parameters
port‐string
Defaults
If port‐string is not specified, local system information will be displayed for all ports.
Mode
Switch command, read‐only.
Example
This example shows how to display the local system information stored for port ge.4.1. Table
describes the output fields of this command. 
C2(rw)->show lldp port local-info
Local Port
--------------------
Port Desc
Mgmt Addr
Chassis ID
Sys Name
Sys Desc
Sys Cap Supported/Enabled
Auto-Neg Supported/Enabled
Auto-Neg Advertised
Operational Speed/Duplex/Type : 100 full tx
Max Frame Size (bytes)
Vlan Id
LAG Supported/Enabled/Id
Protocol Id : Spanning Tree v-3 (IEEE802.1s)
PoE Device
PoE Power Source
PoE MDI Supported/Enabled
PoE Pair Controllable/Used
PoE Power Class
PoE Power Limit (mW)
PoE Power Priority
6-18 Discovery Protocol Configuration
(Optional) Displays local system information for one or a range of 
ports.
ge.
:
4.1
Local Port Id:
: ... 1000BASE-TX RJ45 Gigabit Ethernet Frontpanel Port
: 10.21.64.100
: 00-E0-63-93-74-A5
: LLDP PoE test Chassis
: Enterasys Networks, Inc.
: bridge,router/bridge
: yes/yes
: 10BASE-T, 10BASE-TFD,
: 1522
: 1
: no/no/0
LACP v-1
GVRP
: PSE device
: primary
: yes/yes
: false/spare
: 2
: 15400
: high
ge.
4.1
ge.
4.1
100BASE-TX, 100BASE-TXFD,
1000BASE-TFD,
Bpause
6‐4 