Defaults
None.
Mode
Switch command, read‐write.
Example
This example enables transmitting LLDP traps on ports ge.1.1 through ge.1.6.
C2(rw)->set lldp port trap enable ge.1.1-6
set lldp port med-trap
Use this command to enable or disable sending an LLDP‐MED notification when a change in the
topology has been sensed on the port (that is, a remote endpoint device has been attached or
removed from the port).
Syntax
set lldp port med-trap {enable | disable} port-string
Parameters
enable
disable
port‐string
Defaults
None.
Mode
Switch command, read‐write.
Example
This example enables transmitting LLDP‐MED traps on ports ge.1.1 through ge.1.6.
C2(rw)->set lldp port med-trap enable ge.1.1-6
set lldp port tx-tlv
Use this command to select the optional LLDP and LLDP‐MED TLVs to be transmitted in
LLDPDUs by the specified port or ports. Use the show lldp port local‐info command to display
the values of these TLVs for the port.
Syntax
set lldp port tx-tlv {[all] | [port-desc] [sys-name] [sys-desc] [sys-cap] [mgmt-
addr] [vlan-id] [stp] [lacp] [gvrp] [mac-phy] [poe] [link-aggr] [max-frame] [med-
cap] [med-loc] [med-poe]} port-string
Enables transmitting LLDP‐MED traps on the specified ports.
Disables transmitting LLDP‐MED traps on the specified ports.
Specifies the port or range of ports to be affected.
set lldp port med-trap
SecureStack C2 Configuration Guide 6-25
Need help?
Do you have a question about the SecureStack C2 C2G170-24 and is the answer not in the manual?