set console baud
Mode
Switch command, read‐only.
Example
This example shows how to display all console settings:
C2(su)->show console
Baud
------
9600
set console baud
Use this command to set the console port baud rate.
Syntax
set console baud rate
Parameters
rate
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the console port baud rate to 19200:
C2(su)->set console baud 19200
Downloading a Firmware Image
You can upgrade the operational firmware in the SecureStack C2 switch without physically
opening the switch or being in the same location. There are two ways to download firmware to the
switch:
•
Via TFTP download. This procedure uses a TFTP server connected to the network and
downloads the firmware using the TFTP protocol. For details on how to perform a TFTP
download using the copy command, refer to "copy" on page 3‐43. For information on setting
TFTP timeout and retry parameters, refer to "set tftp timeout" on page 3‐45 and "set tftp
retry" on page 3‐46.
•
Via the serial (console) port. This procedure is an out‐of‐band operation that copies the
firmware through the serial port to the switch. It should be used in cases when you cannot
connect the switch to perform the in‐band copy download procedure via TFTP. Serial console
download has been successfully tested with the following applications:
–
3-30 Basic Configuration
Flow
Bits
StopBits
-------
----
----------
Disable
8
1
Sets the console baud rate. Valid values are: 300, 600, 1200, 2400, 4800, 5760,
9600, 14400, 19200, 38400, and 115200.
HyperTerminal Copyright 1999
Parity
------
none