Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Example
This example shows how to display the current Loop Protect window value:
C2(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds
clear spantree lpwindow
Use this command to reset the Loop Protect event window to the default value of 180 seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to reset the Loop Protect event window to the default of 180 seconds:
C2(rw)->clear spantree lpwindow
set spantree lptrapenable
Use this command to enable or disable Loop Protect event notification.
Syntax
set spantree lptrapenable {enable | disable}
Parameters
enable | disable
Enables or disables the sending of Loop Protect traps. Default is
disabled.
clear spantree lpwindow
SecureStack C2 Configuration Guide 9-49
Need help?