set sntp poll-retry

Example
This example shows how to clear the SNTP poll interval:
C2(su)->clear sntp poll-interval
set sntp poll-retry
Use this command to set the number of poll retries to a unicast SNTP server.
Syntax
set sntp poll-retry retry
Parameters
retry
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the number of SNTP poll retries to 5:
C2(su)->set sntp poll-retry 5

clear sntp poll-retry

Use this command to clear the number of poll retries to a unicast SNTP server.
Syntax
clear sntp poll-retry
Parameters
None.
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear the number of SNTP poll retries:
C2(su)->clear sntp poll-retry
14-32 Logging and Network Management