Filter-Id Attribute Formats; Configuring Radius; Purpose - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

The RADIUS Filter‐ID attribute is simply a string that is formatted in the RADIUS Access‐Accept 
packet sent back from the RADIUS server to the switch during the authentication process. 
Each user can be configured in the RADIUS server database with a RADIUS Filter‐ID attribute 
that specifies the name of the policy profile and/or management level the user should be assigned 
upon successful authentication. During the authentication process, when the RADIUS server 
returns a RADIUS Access‐Accept message that includes a Filter‐ID matching a policy profile name 
configured on the switch, the switch then dynamically applies the policy profile to the physical 
port the user/device is authenticating on. 

Filter-ID Attribute Formats

Enterasys Networks supports two Filter‐ID formats — "decorated" and "undecorated." The 
decorated format has three forms:
To specify the policy profile to assign to the authenticating user (network access 
authentication):
Enterasys:version=1:policy=string
where string specifies the policy profile name. Policy profile names are case‐sensitive.
To specify a management level (management access authentication):
Enterasys:version=1:mgmt=level
where level indicates the management level, either ro, rw, or su.
To specify both management level and policy profile:
Enterasys:version=1:mgmt=level:policy=string
The undecorated format is simply a string that specifies a policy profile name. The undecorated 
format cannot be used for management access authentication.
Decorated Filter‐IDs are processed first by the switch. If no decorated Filter‐IDs are found, then 
undecorated Filter‐IDs are processed. If multiple Filter‐IDs are found that contain conflicting 
values, a Syslog message is generated.

Configuring RADIUS

Purpose

To perform the following:
Review the RADIUS client/server configuration on the switch.
Enable or disable the RADIUS client.
Set local and remote login options.
Set primary and secondary server parameters, including IP address, timeout period, 
authentication realm, and number of user login attempts allowed.
Reset RADIUS server settings to default values.
Configure a RADIUS accounting server.
Configuring RADIUS
SecureStack C2 Configuration Guide 23-3