show linkflap
Examples
This example shows how to display the global status of the link trap detection function:
C2(rw)->show linkflap globalstate
Linkflap feature globally disabled
This example shows how to display ports disabled by link flap detection due to a violation:
C2(rw)->show linkflap downports
Ports currently held DOWN for Linkflap violations:
None.
This example shows how to display the link flap parameters table:
C2(rw)->show linkflap parameters
Linkflap Port Settable Parameter Table (X means error occurred)
Port
--------
ge.1.1
ge.1.2
ge.1.3
Table
7‐3 provides an explanation of the show linkflap parameters command output.
Table 7-3 show linkflap parameters Output Details
Output Field
Port
LF Status
Actions
Threshold
Interval
Downtime
This example shows how to display the link flap metrics table:
C2(rw)->show linkflap metrics
Port
--------
ge.1.1
ge.1.2
ge.1.3
Table
7‐4 provides an explanation of the show linkflap metrics command output.
Table 7-4 show linkflap metrics Output Details
Output Field
Port
LinkStatus
CurrentCount
TotalCount
7-24 Port Configuration
LF Status
Actions
---------
-------
disabled
.......
enabled
D..S..T
disabled
...S..T
LinkStatus
CurrentCount
-----------
------------
operational
0
disabled
4
operational
3
Threshold
Interval
----------
----------
10
5
3
5
10
5
What it displays...
Port designation.
Link flap enabled state.
Actions to be taken if the port violates allowed link flap behavior.
D = disabled, S = Syslog entry will be generated, T= SNMP trap
will be generated.
Number of link down transitions necessary to trigger the link flap
action.
Time interval (in seconds) for accumulating link down transitions.
Interval (in seconds) port(s) will be held down after a link flap
violation.
TotalCount
TimeElapsed
----------
----------- -------------
0
241437
15
147
3
241402
What it displays...
Port designation.
Link status according to the link flap function.
Link down count accruing toward the link flap threshold.
Number of link downs since system start,
Downtime
----------
300
300
300
Violations
0
5
0