Set Linkflap Downtime; Clear Linkflap Down - Enterasys SecureStack C2 C2G170-24 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2 C2G170-24:
Table of Contents

Advertisement

set linkflap downtime

Parameters
port‐string
threshold‐value
Defaults
None.
Mode
Switch mode, read‐write.
Example
This example shows how to set the link flap threshold on port ge.1.4 to 5.
C2(rw)->set linkflap threshold
set linkflap downtime
Use this command to set the time interval (in seconds) one or more ports will be held down after a 
link flap violation.
Syntax
set linkflap downtime port-string downtime-value
Parameters
port‐string
downtime‐value
Defaults
None.
Mode
Switch mode, read‐write.
Example
This example shows how to set the link flap downtime on port ge.1.4 to 5000 seconds.
C2(rw)->set linkflap downtime

clear linkflap down

Use this command to toggle link flap disabled ports to operational.
Syntax
clear linkflap down [port-string]
7-28 Port Configuration
Specifies the port(s) on which to set the link flap action trigger count. 
Specifies the number of link down transitions necessary to trigger the 
link flap action. A minimum of 1 must be configured.
ge.
1.4 5
Specifies the port(s) on which to set the link flap downtime.
Specifies a downtime in seconds. A value of 0 will set the downtime to 
forever.
ge.
1.4 5000

Advertisement