clear summertime

Parameters
start_week 
start_day 
start_hr_min
end_week
end_day
end_hr_min
offset_minutes
Defaults
If an offset is not specified, none will be applied.
Mode
Switch command, read‐write.
Example
This example shows how set daylight savings time to recur starting on the first Sunday of April at 
2 a.m. and ending the last Sunday of October at 2 a.m. with an offset time of one hour:
C2(su)->set summertime recurring first Sunday April 02:00 last Sunday October
02:00 60
clear summertime
Use this command to clear the daylight savings time configuration.
Syntax
clear summertime
Parameters
None.
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to clear the daylight savings time configuration:
C2(su)->clear summertime
3-22 Basic Configuration
Specifies the week of the month to restart daylight savings time. Valid 
values are: first, second, third, fourth, and last.
Specifies the day of the week to restart daylight savings time. 
Specifies the time of day to restart daylight savings time. Format is 
hh:mm.
Specifies the week of the month to end daylight savings time. 
Specifies the day of the week to end daylight savings time.
Specifies the time of day to end daylight savings time. Format is hh:mm.
(Optional) Specifies the amount of time in minutes to offset daylight 
savings time from the non‐daylight savings time system setting. Valid 
values are 1 ‐ 1440.