switches.. Executing this command will reset the switch, so the system prompts you to confirm 
whether you want to proceed.
Syntax
set system enhancedbuffermode {enable | disable}
Parameters
enable | disable
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to enable enhanced buffer mode:
C2(su)->set system enhancedbuffermode enable
Changes in the enhanced buffer mode will require resetting this unit.
Are you sure you want to continue? (y/n)

set system temperature

Use this command to set the system high temperature threshold limit and the high temperature 
alert parameters, on the platforms that support this feature.
Syntax
set system temperature {[syslog enable | disable] [trap enable | disable]
[overtemp-threshold value]}
Parameters
syslog enable | 
disable
trap enable | disable
overtemp‐threshold 
value
Defaults
Syslog alerts are disabled by default.
Trap alerts are disabled by default.
Overtemp threshold is 100% by default.
Mode
Switch command, read‐write.
Enables or disables enhanced buffer mode.
Enables or disables logging high temperature alerts to the system log 
when the system transitions into an alarm state.
Enables or disables sending high temperature alerts by means of SNMP 
traps when the system transitions into an alarm state.
Sets the thermal threshold as a percentage of the maximum rated for the 
specific platform. Value can range from 0 to 100%.
set system temperature