Example
This command shows how to display the Syslog server default values. For an explanation of the 
command output, refer back to Table
C2(su)->show logging default
Defaults:

set logging default

Use this command to set logging default values.
Syntax
set logging default {[facility facility] [severity severity] port port]}
Parameters
facility facility
severity severity
port port
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set the Syslog default facility name to local2 and the severity level to 4 
(error logging):
C2(su)->set logging default facility local2 severity 4
Facility
Severity
-----------------------------------------
local4
warning(5)
Specifies the default facility name. Valid values are: local0 to local7.
Specifies the default logging severity level. Valid values and 
corresponding levels are:
1 — emergencies (system is unusable)
2 — alerts (immediate action required)
3 — critical conditions
4 — error conditions
5 — warning conditions
6 — notifications (significant conditions)
7 — informational messages
8 — debugging messages
Specifies the default UDP port the client uses to send to the server.
14‐1 on page 14‐2.
Port
514
set logging default
SecureStack C2 Configuration Guide 14-5