Keithley 2651A Reference Manual page 599

High power system sourcemeter instrument
Hide thumbs Also See for 2651A:
Table of Contents

Advertisement

Model 2651A High Power System SourceMeter® Instrument Reference Manual
Usage
operationRegister =
status.operation.instrument.tsplink.trigger_overrun.condition
operationRegister = status.operation.instrument.tsplink.trigger_overrun.enable
operationRegister = status.operation.instrument.tsplink.trigger_overrun.event
operationRegister = status.operation.instrument.tsplink.trigger_overrun.ntr
operationRegister = status.operation.instrument.tsplink.trigger_overrun.ptr
status.operation.instrument.tsplink.trigger_overrun.enable = operationRegister
status.operation.instrument.tsplink.trigger_overrun.ntr = operationRegister
status.operation.instrument.tsplink.trigger_overrun.ptr = operationRegister
operationRegister
Details
These attributes are used to read or write to the operation status TSP-link overrun registers. Reading a status
register returns a value. The binary equivalent of the returned value indicates which register bits are set. The
least significant bit of the binary number is Bit B0, and the most significant bit is Bit B15. For example, if a value
of 10 is read as the value of the condition register, the binary equivalent is 0000 0000 0000 1010. This value
indicates that bit B1 and bit B3 are set.
B15
B14
**
>
0
0
* Least significant bit
** Most significant bit
A set bit indicates that the specified line generated an action overrun when triggered to generate an output
trigger.
For information about .condition, .enable, .event, .ntr, and .ptr registers, refer to
2) and
Enable and transition registers
meanings:
Bit
Value
B0
Not used
B1
status.operation.instrument.tsplink.trigger_overrun.LINE1
B2
status.operation.instrument.tsplink.trigger_overrun.LINE2
B3
status.operation.instrument.tsplink.trigger_overrun.LINE3
B4-
Not used
B15
As an example, to set bit B1 of the operation status TSP-Link overrun enable register, set
status.operation.instrument.tsplink.trigger_overrun.enable =
status.operation.instrument.tsplink.trigger_overrun.LINE1.
In addition to the above constants, operationRegister can be set to the numeric equivalent of the bit to set.
To set more than one bit of the register, set operationRegister to the sum of their decimal weights. For
example, to set bits B1 and B3, set operationRegister to 10 (which is the sum of 2 + 8).
2651A-901-01 Rev. A / March 2011
The operation status TSP-link overrun register's status. A zero (0) indicates no bits
set (also send 0 to clear all bits); other values indicate various bit settings
B13
B12
B11
B10
>
>
>
>
0
0
0
0
(on page E-18). The individual bits of this register have the following
B9
B8
B7
B6
>
>
>
>
0
0
0
0
Section 7: Command reference
B5
B4
B3
B2
>
>
>
>
0
0
1
0
Status register sets
Description
Not applicable
Bit B1 decimal value:
2
Bit B2 decimal value:
4
Bit B3 decimal value:
8
Not applicable
B1
B0
>
*
1
0
(on page E-
7-291

Advertisement

Table of Contents
loading

Table of Contents