Configpulsevmeasureisweeplin() - Keithley 2651A Reference Manual

High power system sourcemeter instrument
Hide thumbs Also See for 2651A:
Table of Contents

Advertisement

Section 7: Command reference

ConfigPulseVMeasureISweepLin()

This
KIPulse factory script
each point.
Type
TSP-Link accessible
Function
No
Usage
f, msg = ConfigPulseVMeasureISweepLin(smu, bias, start, stop, limit, ton, toff,
points, buffer, tag, sync_in, sync_out, sync_in_timeout, sync_in_abort)
f, msg = ConfigPulseVMeasureISweepLin(smu, bias, start, stop, limit, ton, toff,
points, buffer, tag, sync_in, sync_out, sync_in_timeout)
f, msg = ConfigPulseVMeasureISweepLin(smu, bias, start, stop, limit, ton, toff,
points, buffer, tag, sync_in, sync_out)
f, msg = ConfigPulseVMeasureISweepLin(smu, bias, start, stop, limit, ton, toff,
points, buffer, tag, sync_in)
f, msg = ConfigPulseVMeasureISweepLin(smu, bias, start, stop, limit, ton, toff,
points, buffer, tag)
f
msg
smu
bias
start
stop
limit
ton
toff
points
buffer
tag
sync_in
sync_out
sync_in_timeout
sync_in_abort
Details
Data for pulsed current measurements are stored in the reading buffer specified by the buffer input parameter.
Configures a linear pulsed voltage sweep with a current measurement at each point. Measurements are made at
the end of the ton time.
7-34
Model 2651A High Power System SourceMeter® Instrument Reference Manual
(on page 5-23) function configures a voltage pulse train with a current measurement at
Affected by
A Boolean flag. This flag will be true when the pulse was successfully configured, false
when errors were encountered
A string message; if the f flag is false, msg will contain an error message; if it is true, msg
will contain a string indicating successful configuration
System SourceMeter
Bias level in volts
Pulse sweep start level in volts
Pulse sweep stop level in volts
Voltage limit (for example, compliance) in amperes
Pulse on time in seconds
Pulse off time in seconds
Number of pulse-measure cycles
Reading buffer where pulsed measurements will be stored; if this is nil when the function is
called, no measurements will be made when the pulse train is initiated
Numeric identifier to be assigned to the defined pulse train
Defines a digital I/O trigger input line; if programmed, the pulse train will wait for a trigger input
before executing each pulse (this parameter is optional)
Defines a digital I/O trigger output line; if programmed, the pulse train will generate a trigger
output immediately before the start of ton (this parameter is optional)
Specifies the length of time (in seconds) to wait for input trigger; default value is 10 s
Specifies whether or not to abort pulse if input trigger is not received. If pulse aborts because
of a missed trigger, a timer timeout message is returned; true or false
Where saved
®
instrument channel (set to smua)
Default value
2651A-901-01 Rev. A / March 2011