Siemens SINUMERIK Commissioning Manual page 98

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Parameterizing machine data
3.1 Handling machine data via the HMI
● Unit of the machine data
● Effectiveness
Effectiveness of the machine data
The right-hand column indicates when a machine data becomes effective:
so = immediately effective
cf = when confirmed via the "Activate MD" softkey
re = reset
po = POWER ON (NCK Power On reset)
Physical units of the machine data
The physical units of machine data are displayed on the right-hand side of the input field:
Display
m/s**2
rev/s**3
kg/m**2
mH
Nm
us
µA
µVs
userdef
If the machine data does not use units, no units are displayed.
If the data are not available, the "#" symbol is displayed instead of the value. If the value
ends in an "H", it is a hexadecimal value.
3.1.1
Setting-up a display filter for machine data
Function
The purpose of the display filters offered for "General machined data" is to selectively reduce
the number of machine data displayed.
For this purpose, all machine data are assigned to certain display groups, e.g. configuration
data. The following applies:
● Each area has its own group organization.
● Each group corresponds to one bit in the word filter (previously a reserve)
92
Unit
m/s²
rev/s³
kgm²
mH (millihenry):
Nm (Newton meters):
µs (microseconds):
µA (microamperes):
µVs (microvolt-seconds):
user-defined:
Measured quantity
Acceleration
Acceleration change for the rotating axis
Moment of inertia
Inductance
Torque
Time
Current magnitude
Magnetic flux
The units are defined by the user.
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
HMI Advanced (IM4)

Hide quick links:

Advertisement

Table of Contents
loading