Siemens SINUMERIK Commissioning Manual page 157

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

5.5.2
Displaying system resources
Function
The system resources for the NCU are displayed in the dialog "NC utilization":
● The net and overall runtime of the position controller, the interpolator and the pre-run in
● NCU load level as a percentage
● Buffer filling level as a percentage
The display update is stopped using the "Stop" softkey, the displayed values are updated
again with the "Start" softkey.
5.5.3
Output of configuration data
Function
The configuration data of a machine (HMI version, NCU version, axis configuration, drive
configuration, bus parameters, active bus nodes) can be written into a file and subsequently
read out or printed.
Configuration data is output in 2 stages:
● Creation of the configuration data file CONFIGURATION_DATA in the "Diagnostics"
● Read-out of the CONFIGURATION_DATA file in the "Services" operating area. To do
Procedure:
1. Select the menu "Service displays".
2. The horizontal softkey bar changes
3. Press the "Config. data" softkey.
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
milli-seconds
operating area by pressing the "Config. data" softkey.
this, the configuration file CONFIGURATION_DATA is generated.
The system gathers the configuration data, writes it into the file CFGDAT.TXT and
displays it. The path and name of the file are output in the info line.
Diagnostics and service
5.5 Service displays
151

Hide quick links:

Advertisement

Table of Contents
loading