Parameterizing machine data
3.2 Parameterizing the control using machine data
3.2.11
Representing the spindle utilization
Function
Up to now, the display range of the spindle utilization in the Machine main screen was
represented at 100%. You can set the display range of the bar graph for representation of
the spindle load to 200% using display MD 9429: MA_SPIND_POWER_RANGE.
9428
MD number
Default setting: 100
Changes effective after: POWER ON
Data type: WORD
Significance
9429
MD number
Default setting: 100
Changes effective after: POWER ON
Data type: WORD
Significance
108
$MM_MA_SPIND_MAX_POWER
Maximum value of the spindle power display
Min. input limit: 100
Protection level: 3/4
In this MD, enter the factor by which the supplied spindle utilization will be
multiplied.
$MM_MA_SPIND_POWER_RANGE
Display range for spindle utilization
Min. input limit: 100
Protection level: 3/4
In this MD, you specify the display range of the bar graph for the spindle
utilization display. Depending on the value entered, the percentage values
displayed and the extent of the color areas change.
Value 100:Percentage values 0%, 80%, and 100% are displayed. The color
display changes from green to red starting at 80% if a value of 100 is also set
in display MD 9428.
Value > 100, e.g. 200:Percentage values 0%, 200%, and 100% are displayed.
The color display changes from green to red starting at 100%.
If you set the value to 200, you must enter the normalization factor in display
MD $MM_MA_SPIND_MAX_POWER.
Max. input value: ****
Units: %
Applies from SW version: 6.4
Max. input value: ****
Units: %
Applies from SW version: 6.4