Siemens SINUMERIK Commissioning Manual page 129

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Configurations 2 to 4: No block search is performed in the other channels (in contrast to the
current channel); "program test" mode is active in the other channels until a stop condition
(e.g. WAITMC) is detected.
Setting the search configuration
The various configurations are activated in the MACHINE.INI file.
The following settings are possible:
[BlockSearch]
SeruproEnabled=1
; Shows (SeruproEnabled=1) or hides (SeruproEnabled=0) the softkey
used to do a block search in "program test" mode. The softkey
appears in both dialogs "Blocksearch Searchposition" and
"Blocksearch Searchpointer"
SeruproEnabled=0
SeruproConfig=1
Changes take effect immediately, i.e., with the next search.
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
=0
Function inactive
=1
Function active (default setting)
=1
Block search in currently selected channel
(default setting)
=2
Block search in currently selected channel and in
all channels with the same workpiece
=3
Block search in currently selected channel and in
all channels with the same mode group
=4
Block search in all channels
4.5 Starting a block search across several channels
Programming PLC Functions
123

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents