Tool management
6.2 Settings in the configuration file
; "TC_DPCS1" to "TC_DPCS10"
; The tool cutting edge user data must be activated on the NC
; and the numbers must be permissible on the NC.
; Cutting edge monitoring user data:
; "TC_MOPCS1" to "TC_MOPCS10"
; The cutting edge monitoring user data must be activated on the NC
; and the numbers must be permissible on the NC.
; Condition:
"==" equal
">" less than
">" greater than
"<=" less than or equal to
">=" greater than or equal to
; && Bit-wise AND, only permissible for operands of type
; WORD and DOUBLEWORD
; "==" is the only relational operator allowed for
; string operands
; Comparison value: String for TC_TP2 (tool data,
; tool identifier),
; max. 32 characters, no spaces before or after
; 0 ... 65535 for all other TC_TP data
; Double for all other data
; Max. one column with additional data can appear for
; each filter.
; _FindResultAddColumnBtss:
; Additional data, OPI item acc. to OPI documentation
(mmc2\btss_gr.hlp).
; Example 1: "/Tool/User/data[u#TOA#,c2,#TNO#](|"!d%.#RES#lf")"
; Tool OEM parameter 2, floating-point notation
; Standard number of decimal places
; Example 2: "/Tool/User/data[u#TOA#,c3,#TNO#](|"!l%ld")"
; Tool OEM parameter 3, integer notation
; Example 3:
"/Tool/MagazineDescription/userData[u#TOA#,c#MAG#,1](|)"
; Magazine OEM parameter 1
; The following placeholders are permissible: #TOA#, #TNO#, #MAG#,
#RES#.
; #TOA# TOA number (of the current channel)
; #TNO# Internal T number (of the tool found)
; #MAG# Magazine number (of the tool found)
; #RES# Standard value for the number of decimal places
; Placeholders are substituted by the data for the current tool or
; by general settings.
; Max. 1 OPI item is permitted.
; "(|)" is entered in front of the result data to generate the data
; separation character "|".
; OPI multiple variable accesses are generated internally from the
OPI item.
; The OPI item must be enclosed by " ",