Commissioning a system
1.1
Delivery condition of the system
Overview
The high-performance SINUMERIK PCU 50.3 has onboard interfaces for communicating via
Ethernet, MPI and PROFIBUS DP. The integrated free slots remain free for other tasks. The
PCU 50.3 is equipped with the Windows XP ProEmbSys operating system and for data
backup tasks with the Symantec Ghost software.
Interfaces:
● Four USB ports (USB 2.0) offer points where a keyboard, mouse and other peripheral
● For CF cards, there is a covered slot.
● For use with SINUMERIK 840D/840D sl:
● For use with SINUMERIK 840Di sl:
For commissioning:
● Two 7-segment displays and two LEDs are integrated for diagnostic purposes. They
● If the PCU is to be operated without an operator panel front, a monitor and an additional
References: Operator Components and Networking Manual
PCU-Basesoftware (IM8)
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
devices can be connected.
Two internal PCI slots are available for specific expansions.
A PCI slot is already equipped with the MCI2 board and can be equipped with the
optional MCI board extension.
indicate the current operating status and display the BIOS error codes during boot up.
keyboard will also be required:
– For diagnostics when booting the PCU
– When installing a replacement hard disk
(alternatively, the hard disk can also be installed externally).
1
5

Hide quick links: