Commissioning a system
1.1 Delivery condition of the system
Changes to Windows services
Other default settings:
Windows services:
Computer Browser
Error Reporting Service
Portable Media Serial Number
SSDP Discovery Service
Universal Plug and Play Host
Web Client
Wireless Zero Configuration
Name of the PCU
Upon delivery of the system, a unique computer name is generated which can be read out
under: "Start" → "Settings" → "Control Panel" → "System", "Computer Name" tab.
Pre-configuration of the PCU
The PCU 50.350.3 has two Ethernet interfaces that are suitably preset with the SINUMERIK
solution line for connecting to the system network.
References: Operator Components and Networking Manual, Networking Chapter
See also
How to set the IP address of the PCU 50.3 (Page 34)
8
Start-up type:
Manual
Disabled
Manual
Disabled
Disabled
Manual
Manual
Eth 1 is preset as a default DHCP client for connection to a
company network.
Eth 2 is preset as a SINUMERIK DHCP server for connection to a
system network. Eth 2 is preset to the fixed IP address
192.168.214.241.
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
(Not started)
(Not started)
(Not started)
(Not started)
PCU-Basesoftware (IM8)

Hide quick links: