Siemens SINUMERIK Commissioning Manual page 166

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

Diagnostics and service
5.7 HMI Analyzer
5.7
HMI Analyzer
5.7.1
Using the HMI Analyzer
Use
The HMI Analyzer diagnoses any problems occurring on a PCU 50.3. The result of the
analysis is displayed via the HMI Analyzer in lists. It can also be stored in ASCII files and
analyzed later. In this way, the differences between the supplied versions and a customer-
modified version can be determined.
Function
All settings of the INI files of HMI-Advanced are analyzed and the resulting settings are
displayed.
Further analyses are possible via the listing of DDE messages, monitoring of the processes,
memory utilization and network settings.
Configuring the HMI Analyzer
The HMI Analyzer is configured in the HMIAnalyzer.ini file:
[HMI_DIRS]
DIR01 = MMC2b
DIR02 = HMI_ADV
DIR03 = ADD_ON
DIR04 = OEM
DIR05 = USER
[HMI_FILES]
FILE01 = MMC.INI
FILE02 = REGIE.INI
FILE03 = MBDDE.INI
FILE04 = OEMFRAME.INI
FILE05 = NETNAMES.INI
FILE06 = KEYS.INI
[Additional]
FILE01 = F:\Programs\Test1.ini
FILE02 = F:\Programs\Test2.ini
Section [HMI_DIRS]
All the directories that are to be used for analyzing the INI files are entered here.
Section [HMI_FILES]
All the INI files that are to be used for analysis are entered here. At the same time, the files
in the directories that are entered under HMI_DIRS are searched and analyzed.
160
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
HMI Advanced (IM4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents