Parameterizing machine data
3.2 Parameterizing the control using machine data
Example:
Program
N110 X100
N110 X100
N120 X0
N130 $P_PFRAME=CTRANS(X,10)
N140 X100
N150 ...
Note
To set the actual-value display: see the machine manufacturer's information.
3.2.3
Changing the access level for the "Basis WO" softkey
Parameters operating area
MD 9247: $MM_USER_CLASS_BASE_ZERO_OFF_PA can be used to set the access level
from which the "Base WO" softkey is displayed in the "Work offset" window in the
"Parameters" operating area. At the same time, the basic frames are also displayed or
hidden in the "Work offset" window and in the "Active WO + compensations" window.
Machine operating area
MD 9248: $MM_USER_CLASS_BASE_ZERO_OFF_MA can be set to select the access
level from which "WO base" softkey is displayed in the "Scratching" screen in the Machine
operating area or G500 can be entered in the work offset field.
3.2.4
Redefining access levels for NC data
Function
The preset access levels can be modified in the definition file. For machine data, only lower
access levels than the configured access level are permitted; for setting data, higher levels
are also permitted. The file becomes active when the next _N_INITIAL_INI is read in.
Different access levels are specified for writing or reading (parts program or PLC).
Example:
_N_DEF_DIR/_N_SGUD_DEF
REDEF $MA_CTRLOUT_SEGMENT_NR APR 7 APW 4 MD 30100
100
WCS display
100
0
0
100
; File for global variables
; $PATH=/_N_DEF_DIR
; (APR ... Read access)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
SZS display
100
0
0
110
HMI Advanced (IM4)