Presently, only the following setting is available:
0: Cache is not active.
1: Cache is active.
[DefaultIcons]
These icons are displayed if icons are not specified in the individual definitions, e.g. if an icon
is not included in SEFORM(...). This icon must be located in the directory that was specified
under IconPath.
Block
Icon for main step – SEFORM(..., 0, ...)
SubBlock
Icon for sub-step – SEFORM(..., 1, ...)
Sync
Icon for synchronization marks – e.g. WAITM(...)
Cycle
Icon for cycle
GeoProz
Icon for contour path
[SyncMarks_User]
Machine manufacturers can enter their expansions for synchronization marks here.
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
List of the INI Files
A.23 SEDITOR.INI